4-6-10 Counter reset input
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
T5
T1
T2
T3
T1
T4
SELECT 0 - 2 IN (No.19-21)
D0 - D15 IN (No.3-18)
SET IN (No.2)
*1
*2
TRIGGER IN (X5)
READY OUT (Y5)
PROCESSING OUT (Y10)
SET OK OUT (No.28)
Item
Time
Remarks
T1
2ms or more
Keep the ON status for 2ms or more.
T2
0ms or more
Keep the input until SET OK OUT (No.28) turns on.
T3
2 to 510ms
One-shot output. Set the output time on the system settings screen. There is a small
margin of error for the setting value.
T4
0ms or more
Turn on TRIGGER IN (X5) after SET OK OUT (No.28) turns on.
T5
0.5ms or more
After a lapse of 0.5ms or more from specifying SELECT 0 IN to SELECT 2 IN and D0 IN to
D15 IN, turn on SET IN (No.2).
*1 : To reset the counter, set SELECT 0 IN to SELECT 2 IN as follows.
SELECT 0 IN (No.19): OFF, SELECT 1 IN (No.20): OFF, SELECT 2 IN (No.21): ON
*2 : Specify the counter number to reset by using D0 IN to D15 IN (No.3 to 18). The following counter numbers are
assigned to D0 IN to D15 IN respectively.
• D0 to D3: Counter No. 0 to 3
• D4 to D7: Common Counter No. 16 to 19
• D8 to D11: Counter No. 4 to 7
• D12 to D15: Common Counter No. 20 to 23
ME-LPGS-SM-8
Содержание LP-GS Series
Страница 17: ...1 Product Overview ME LPGS SM 8 ...
Страница 32: ...2 Laser Marker Installation ME LPGS SM 8 ...
Страница 48: ...3 Operation Method ME LPGS SM 8 ...
Страница 68: ...4 External Control Using I O ME LPGS SM 8 ...
Страница 107: ...5 External Control by Communication Commands ME LPGS SM 8 ...
Страница 116: ...6 Link Control with External Devices ME LPGS SM 8 ...
Страница 141: ...7 Maintenance ME LPGS SM 8 ...
Страница 161: ...161 MEMO ME LPGS SM 8 ...
Страница 162: ...Troubleshooting ME LPGS SM 8 ...
Страница 186: ...Index ME LPGS SM 8 ...
Страница 188: ...188 Unit power cable 26 USB 30 45 V Vibration resistance 33 W Warning 177 Z Z axis adjustment module 154 ME LPGS SM 8 ...
Страница 189: ......
Страница 190: ... Panasonic Industrial Devices SUNX Co Ltd 2014 2019 April 2019 ...