ERROR
CODE
Description
Measures *1
E625
No response from the image checker. Trigger
processing terminated abnormally.
• Check the connecting status of the laser marking
system and image checker.
• Check if the reading process of the image checker
was successful.
• If you use PV230/PV200, set the total judgement.
E626
Settings mismatch between image checker
and laser marking system. Trigger processing
terminated abnormally.
• Check the settings of application, type number, and
checker number.
• Check the conformity of the Ethernet settings
with the General communication of PV230/PV200
protocol.
E627
The link control between the laser marker and
image checker has failed.
No settings for code or character checking
available.
• Verify “Object number to check” in file settings,
and confirm if the number is the same with
the object number you set in barcode/2D code
settings or character settings.
• For the code checking, confirm the code type and
settings of barcode/2D code object in the marking
data are consistent with the settings of the code
reader.
• For the character checking, check if the character
type and number of characters in the marking data
are supported by the image checker.
E628
Code reading failed when the code reading
function is used for the link control with external
devices.
• Check the status of external devices.
• Improve the marking quality of the code.
• To send the marking strings or to switch the files
by using code reader, confirm the followings:
• Confirm no unavailable characters are in the
code data.
• When using the data extraction function,
confirm the data length in the code data
matches the extraction settings.
• When you do not use the data extraction
function, set the code data less than 299
digits.
E629
File switching by code reader has failed.
• Confirm the specified file number or name exactly
corresponded to the settings in the laser marker.
• To switch the file by the number, specify the
number always with 4-digits in the code data.
• If no settings in the specified file, set the marking
data and save that file to the laser marker.
E630
TRIGGER IN turned off before the minimum
number of scans was reached.
• Confirm the on/off control of the TRIGGER IN on
the I/O terminal.
• If TRIGGER IN turns on/off properly, change the
setting value of Minimum number of scans of
Trigger mode in File settings.
E631
Lasing stopped because the maximum number
of scans was reached.
• Confirm the on/off control of the TRIGGER IN on
the I/O terminal.
• If TRIGGER IN turns on/off properly, change the
setting value of Maximum number of scans of
Trigger mode in File settings.
ME-LPGS-SM-8
Содержание LP-GS Series
Страница 17: ...1 Product Overview ME LPGS SM 8 ...
Страница 32: ...2 Laser Marker Installation ME LPGS SM 8 ...
Страница 48: ...3 Operation Method ME LPGS SM 8 ...
Страница 68: ...4 External Control Using I O ME LPGS SM 8 ...
Страница 107: ...5 External Control by Communication Commands ME LPGS SM 8 ...
Страница 116: ...6 Link Control with External Devices ME LPGS SM 8 ...
Страница 141: ...7 Maintenance ME LPGS SM 8 ...
Страница 161: ...161 MEMO ME LPGS SM 8 ...
Страница 162: ...Troubleshooting ME LPGS SM 8 ...
Страница 186: ...Index ME LPGS SM 8 ...
Страница 188: ...188 Unit power cable 26 USB 30 45 V Vibration resistance 33 W Warning 177 Z Z axis adjustment module 154 ME LPGS SM 8 ...
Страница 189: ......
Страница 190: ... Panasonic Industrial Devices SUNX Co Ltd 2014 2019 April 2019 ...