4.
Disconnect the two (2) connectors of the fans and
remove them from the controller.
(One connector for one fan)
5.
Loosen the screws (4 screws for 1 fan), and
remove the fan guard and the fan itself from the
head.
6.
Remove dust and dirt adhered onto the fan by air-blowing.
ワㄐㄕㄊㄆ
• Do not rinse the fan. This may cause failure of the electronic parts inside.
7.
Install the fan guard against the direction of arrow on the side of
the fan indicating the air flow, as shown in the figure on the right
(intake direction).
ワㄐㄕㄊㄆ
• Install the head fan in the direction so that the air flow matches the intake direction.
Fan installed in the wrong way causes the flow to go in the wrong way, which may
failure of the product.
Fan guard
Fan
Screws
Fan guard
Airflow direction
Fan
Screws