182
ERROR
CODE
Description
Measures *1
E661
Insufficient marking memory. Marking data in the
file are too large.
• Reduce the number of characters and segments
in the graphic data.
• Reduce the number of characters and start/end
points of the graphic data.
• Reduce the number of markings for Step & repeat.
• Separate the long segment into short data.
E662
The number of Step & repeat marking exceeds
the upper limit.
Reduce objects to be marked to 10000 or less.
E664
One or more functions that cannot be used
together are set.
The following combination of the functions are
not available in one file.
• Characters specified by SIN command and
registered characters via I/O
• Characters specified by SIN command and
external offset function with I/O
• Registered characters via I/O and external
offset function with “Using SEO command”
• Link control with an image checker and
“continuous trigger” of trigger mode
• For LP-RC/LP-RF/LP-RV series:
Link control with an image checker and
TARGET DETECTION IN
Delete any one of these functions from the file.
E665
It contains character(s) that cannot be converted
to 2D code.
• Set the character that can be converted into 2D
code.
• Change the mode of the code settings.
E666
• Unable to generate 2D code in the condition
specified.
• The number of 2D code characters is too
large relative to the set conditions.
Check the code settings and the number of
characters.
E667
The specified 2D code filling pattern is not
registered for the 2D code font (font number:
2D).
• Change the 2D code filling pattern.
• Add the font data of the pattern used in the data
management screen.
E668
The data includes a character that cannot be bar
coded.
Set characters that can be bar-coded depending on
the code type.
E669
• Unable to generate bar code in the condition
specified.
• The number of bar code characters is
incorrect relative to the set conditions.
Check the code settings and the number of
characters.
E670
The dimensions of the narrow element or the
module width for the bar code are too small.
Specify the setting value for the narrow element or
the module width larger than that of the “line width
(calculation value)” specified in the object group
settings.
E671
The quiet zone is not configured correctly at the
bar code inversion mode settings.
Set the proper value for “Quiet/Narrow Ratio”.
ME-LPGS-SM-8
Содержание LP-GS Series
Страница 17: ...1 Product Overview ME LPGS SM 8 ...
Страница 32: ...2 Laser Marker Installation ME LPGS SM 8 ...
Страница 48: ...3 Operation Method ME LPGS SM 8 ...
Страница 68: ...4 External Control Using I O ME LPGS SM 8 ...
Страница 107: ...5 External Control by Communication Commands ME LPGS SM 8 ...
Страница 116: ...6 Link Control with External Devices ME LPGS SM 8 ...
Страница 141: ...7 Maintenance ME LPGS SM 8 ...
Страница 161: ...161 MEMO ME LPGS SM 8 ...
Страница 162: ...Troubleshooting ME LPGS SM 8 ...
Страница 186: ...Index ME LPGS SM 8 ...
Страница 188: ...188 Unit power cable 26 USB 30 45 V Vibration resistance 33 W Warning 177 Z Z axis adjustment module 154 ME LPGS SM 8 ...
Страница 189: ......
Страница 190: ... Panasonic Industrial Devices SUNX Co Ltd 2014 2019 April 2019 ...