Settings of PV230/PV200 for position correction
When PV230/PV200 is used for position correction, set the following items:
1.
In PV230/PV200 setting software, select “Type” -
“Type Setting” - “Camera” - “Calibration” and set
the following items.
• Calibration: Available
• Method: Base X points
2.
Mark the calibration marks with the laser marker
and register their coordinates (mm) to the global
coordinates of PV230/PV200.
ンㄆㄇㄆㄓㄆㄏㄆ
• The calibration is necessary to convert the coordinates (pixel) of
PV230/PV200 to the X-/Y-coordinates (mm) of the laser marker.
• After the calibration, confirm that in PV230/PV200 the CCW
direction of the θ-correction is on the positive (+) side.
3.
Set one of the followings to detect the correction value of the position for the laser marking.
• “Inspection” - “Position Adjustment”
• “Inspection” - “Checker” - Set “Smart edge (Line)”, “Smart matching”, or other checker that includes the angle value.
4.
Select “Inspection” - “Numerical Calculation”. Set
the coordinates in the order of X, Y, theta in the
expression table, that you want to send to the
laser marker for the positional correction. Then,
set “Yes” to “Output” of each expression.
ンㄆㄇㄆㄓㄆㄏㄆ
• The results of the numerical calculation should output to the laser marker in the order of X, Y, and theta.
• The rotation center of PV230/PV200 corresponds to the center of the marking field of the laser marker. (When X- and
Y-movement in the file settings of the laser marker are set to 0mm.)
• The correction value of theta, X-and Y-position by PV230/PV200 are added respectively to the rotation movement, X-
and Y-movement in the file settings of the laser marker.
• The laser marker corrects the theta-coordinate with the rotation origin of the center of the marking field first. Then, X-/
Y-coordinates are corrected.
5.
Select “Inspection” - “Judgement” and set “JDC
(External)” to “Type”.
6.
Set the result of the checker for the positional
correction in the expression table.
7.
Select “Set” of Condition, and set “JDC” to
Condition and specify “Checker No.” of Total
Judgement.
+Y
(0, 0)
+X
-X
-Y
+Y
(0, 0)
+X
Coordinates of
PV230/PV200
Coordinates of
laser marker
ME-LPGS-SM-8
Содержание LP-GS Series
Страница 17: ...1 Product Overview ME LPGS SM 8 ...
Страница 32: ...2 Laser Marker Installation ME LPGS SM 8 ...
Страница 48: ...3 Operation Method ME LPGS SM 8 ...
Страница 68: ...4 External Control Using I O ME LPGS SM 8 ...
Страница 107: ...5 External Control by Communication Commands ME LPGS SM 8 ...
Страница 116: ...6 Link Control with External Devices ME LPGS SM 8 ...
Страница 141: ...7 Maintenance ME LPGS SM 8 ...
Страница 161: ...161 MEMO ME LPGS SM 8 ...
Страница 162: ...Troubleshooting ME LPGS SM 8 ...
Страница 186: ...Index ME LPGS SM 8 ...
Страница 188: ...188 Unit power cable 26 USB 30 45 V Vibration resistance 33 W Warning 177 Z Z axis adjustment module 154 ME LPGS SM 8 ...
Страница 189: ......
Страница 190: ... Panasonic Industrial Devices SUNX Co Ltd 2014 2019 April 2019 ...