81
No.
Name and description
t
Data number to switch when using the registered characters/external offset function (SELECT 0 IN: ON)
The registered characters/external offset function is a function that switches marking characters (registered
characters) or the position (external offset) using the input terminal D0 to D15. Configure the character or
coordinate patterns to the data number corresponding to D0 to D15 in advance. Specify which pattern you
will mark from D0 to D15.
Specify the data number in the binary system as D0 to D15 and turn ON SET IN (No.2).
The data numbers corresponding to D0 to D15 are defined as follows according to the settings.
I/O input condition settings *
Terminal
Data number target
Data number
Registered characters: 4-bit × 4
D0 to D3
Registered character table 0
0 to 15
D4 to D7
Registered character table 1
0 to 15
D8 to D11
Registered character table 2
0 to 15
D12 to D15
Registered character table 3
0 to 15
Registered characters: 8-bit × 2
D0 to D7
Registered character table 0
0 to 255
D8 to D15
Registered character table 1
0 to 255
External offset: Lower 4 bits
D0 to D3
External offset
0 to 15
External offset: Lower 8 bits
D0 to D7
External offset
0 to 255
External offset: Lower 10 bits
D0 to D9
External offset
0 to 1023
* You can also use the registered characters via I/O together with the external offset function. If you use
the same terminal for both the registered characters and external offset at this time, the input status will
be reflected to the data number of both functions.
Example: Specify data number 15 when using lower 8 bits
Select “0000 1111”, which represents 15 in a 8-bit binary system, by specifying ON/OFF of D0 to D7 as
shown in the below table. (D0 is the lowest digit number.)
D0 to D7: Data number of registered characters/external offset (the lower 8 bits are used)
Terminal
Data number (binary)
Input
D0
1
ON
D1
1
ON
D2
1
ON
D3
1
ON
D4
0
OFF
D5
0
OFF
D6
0
OFF
D7
0
OFF
ME-LPGS-SM-8
Содержание LP-GS Series
Страница 17: ...1 Product Overview ME LPGS SM 8 ...
Страница 32: ...2 Laser Marker Installation ME LPGS SM 8 ...
Страница 48: ...3 Operation Method ME LPGS SM 8 ...
Страница 68: ...4 External Control Using I O ME LPGS SM 8 ...
Страница 107: ...5 External Control by Communication Commands ME LPGS SM 8 ...
Страница 116: ...6 Link Control with External Devices ME LPGS SM 8 ...
Страница 141: ...7 Maintenance ME LPGS SM 8 ...
Страница 161: ...161 MEMO ME LPGS SM 8 ...
Страница 162: ...Troubleshooting ME LPGS SM 8 ...
Страница 186: ...Index ME LPGS SM 8 ...
Страница 188: ...188 Unit power cable 26 USB 30 45 V Vibration resistance 33 W Warning 177 Z Z axis adjustment module 154 ME LPGS SM 8 ...
Страница 189: ......