174
ERROR
CODE
Description
Measures *1
E205 - E207
• Abnormality occurs on the internal shutter.
• Signal cable is not connected properly.
Check the connection of the cable and various
signal lines, and then restart the laser marker.
E220
Laser head housing is open.
Contact our sales office or representatives.
E225 *4
Fiber unit is detached.
Install the fiber unit properly by following the
procedures described in the Setup/Maintenance
Guide.
E250 - E252
E260 - E261
E264 - E265
• An error has occurred to the laser oscillator.
• A power supply voltage error was detected in
the laser oscillator.
• Incorrect connection of signal cable or unit
power cable.
• Check and correct the power status.
• Check if the AC power line is effected by noise.
• Check the connection of the cable and various
signal lines, and then restart the laser marker.
• For LP-RC series:
Check if the ambient temperature of the
laser marker is not exceeding the range of its
specification.
E262 *4
Temperature error in laser oscillator.
• Check if the ambient temperature of the
laser marker is not exceeding the range of its
specification.
• Make sure air-cooling fan operates.
• Remove the dust and contamination in the
air intake and exhaust port, and clean the air-
cooling part such as fan and filter.
• When not recovered, contact our sales office
or representatives.
E263 *4
Detected unintended-irradiation.
Contact our sales office or representatives.
E270 - E275
E277
E280 - E285
E287
• An error has occurred to the galvano scanner
of the head.
• Incorrect connection of signal cable or unit
power cable.
• Check and correct the power status.
• Check if the AC power line is effected by noise.
• Check the connection of the cable and various
signal lines, and then restart the laser marker.
Marking data are too detailed for the scan speed
configured.
Decrease the scan speed.
E290 - E291
*2
An error has occurred to the Z-axis adjustment
module.
Check the connection of the cable and various
signal lines, and then restart the laser marker.
E400
INTERLOCK 1 of the I/O terminal block was
released.
• Connect INTERLOCK terminals on the I/O
terminal block.
• Check the status of the safety equipment
connected to INTERLOCK terminal.
• Confirm operation logic of connection device.
• For LP-RC/LP-RF/LP-RV series:
If the error cannot be solved even with the
proper connection of INTERLOCK terminals,
replace the contactor for INTERLOCK by
following the procedures described in the
Setup/Maintenance Guide.
E401
INTERLOCK 2 of the I/O terminal block was
released.
ME-LPGS-SM-8
Содержание LP-GS Series
Страница 17: ...1 Product Overview ME LPGS SM 8 ...
Страница 32: ...2 Laser Marker Installation ME LPGS SM 8 ...
Страница 48: ...3 Operation Method ME LPGS SM 8 ...
Страница 68: ...4 External Control Using I O ME LPGS SM 8 ...
Страница 107: ...5 External Control by Communication Commands ME LPGS SM 8 ...
Страница 116: ...6 Link Control with External Devices ME LPGS SM 8 ...
Страница 141: ...7 Maintenance ME LPGS SM 8 ...
Страница 161: ...161 MEMO ME LPGS SM 8 ...
Страница 162: ...Troubleshooting ME LPGS SM 8 ...
Страница 186: ...Index ME LPGS SM 8 ...
Страница 188: ...188 Unit power cable 26 USB 30 45 V Vibration resistance 33 W Warning 177 Z Z axis adjustment module 154 ME LPGS SM 8 ...
Страница 189: ......
Страница 190: ... Panasonic Industrial Devices SUNX Co Ltd 2014 2019 April 2019 ...