92
4-6 Basic Control Timing Chart
ンㄆㄇㄆㄓㄆㄏㄆ
• ON/OFF on the timing chart refers to ON/OFF operations. It does not refer to the voltage level (High/Low).
• In the following timing charts, the timing of output operation corresponding to the each input has a small delay of 0ms or
more.
4-6-1 Flow from startup to marking
T1
T5
T2
T4
T4
T7
T6
T3
T3
T3
T3
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
(Open)
(Close)
ON
OFF
(Open)
(Close)
ON
OFF
(Normal)
(Error)
ON
OFF
(Normal)
(Error)
REMOTE IN (X4)
*1
LASER SUPPLY IN (X6)
SHUTTER ENABLE IN (X9)
SHUTTER IN (X8)
TRIGGER IN (X5)
SYSTEM STANDBY OUT
(Y7)
REMOTE OUT (Y4)
LASER STANDBY OUT (Y6)
ALARM OUT (Y15)
WARNING OUT (Y14)
READY OUT (Y5)
PROCESSING OUT (Y10)
LASING OUT (Y20)
PROCESSING END OUT
(Y11)
SHUTTER OPEN 1 OUT (Y8)
SHUTTER OPEN 2 OUT (Y9)
Key switch
*1 : Turn off the key switch with the laser pumping turned off or with the shutter closed.
ME-LPGS-SM-8
Содержание LP-GS Series
Страница 17: ...1 Product Overview ME LPGS SM 8 ...
Страница 32: ...2 Laser Marker Installation ME LPGS SM 8 ...
Страница 48: ...3 Operation Method ME LPGS SM 8 ...
Страница 68: ...4 External Control Using I O ME LPGS SM 8 ...
Страница 107: ...5 External Control by Communication Commands ME LPGS SM 8 ...
Страница 116: ...6 Link Control with External Devices ME LPGS SM 8 ...
Страница 141: ...7 Maintenance ME LPGS SM 8 ...
Страница 161: ...161 MEMO ME LPGS SM 8 ...
Страница 162: ...Troubleshooting ME LPGS SM 8 ...
Страница 186: ...Index ME LPGS SM 8 ...
Страница 188: ...188 Unit power cable 26 USB 30 45 V Vibration resistance 33 W Warning 177 Z Z axis adjustment module 154 ME LPGS SM 8 ...
Страница 189: ......
Страница 190: ... Panasonic Industrial Devices SUNX Co Ltd 2014 2019 April 2019 ...