Device Configuration
SECTION 6 Projects
83
If a timeout occurs, the communication is not complete. Where necessary,
increase the Timeout Offset value (in milliseconds) to ensure that the device
does not cause a timeout.
Values specified may be set as default by clicking the Make Default button.
6-7-2
Modifying a PLC Connection
From the Setup Devices dialog box, a PLC name may be modified by
selecting the PLC name from the Device List on the Setup Devices dialog box,
and clicking the
Modify
button. This opens the Change PLC dialog box.
A new name can be entered in the PLC Name: field. If an invalid PLC name is
entered, an error message opens on clicking the OK button.
6-7-3
Removing a PLC Connection
From the Setup Devices dialog box, a PLC name may be removed from the
PLC Name: field by selecting the PLC name from the Device List on the
Setup
Devices
dialog box, and clicking the
Delete
button. This results in a
confirmation dialog box being displayed. Click the
Yes
button to remove the
PLC from the list, or the No button to abort the delete operation.
Note:
The possible settings for the Baud Rate, Parity, Data Bits, and Stop Bits fields
depend upon the port selected.
Note:
A PLC cannot be renamed, deleted or edited if it is currently open for
communications.
Содержание CX-Supervisor
Страница 1: ...CX Supervisor Software Cat No W10E EN 01 User Manual Software Release 3 1...
Страница 3: ...Copyright Notice 2...
Страница 16: ...15...
Страница 17: ...16...
Страница 27: ...Tip of the Day SECTION 1 Graphics Editor 26...
Страница 35: ...CX Supervisor Preferences SECTION 2 Pages 34...
Страница 79: ...Responding to Events SECTION 5 ActiveX Objects 78...
Страница 115: ...Printing the Graphics Library SECTION 7 Graphics Library 114...
Страница 181: ...Data Logging SECTION 11 Data Logging 180...
Страница 201: ...Examples SECTION 12 Databases 200...
Страница 243: ...Performance Monitor SECTION 16 Application Analysis Performance Monitor 242...
Страница 253: ...Using with Omron s CX Server OPC SECTION 17 Using CX Supervisor as an OPC Cli 252...
Страница 259: ...Creating a CX Supervisor Client application SECTION 18 Connecting to a remote CX 258...
Страница 263: ...Adding a Point Linked to a Parameter SECTION 19 Connecting to Omron Industrial 262...
Страница 271: ...Data Logging SECTION 20 Best Practices 270...
Страница 275: ...Configuring a Server PC running Windows NT or 2000 Appendix A Configuring a PC 274...
Страница 277: ...Appendix B Frequently Asked Questions 276...
Страница 296: ...Appendix B Frequently Asked Questions 295...
Страница 297: ...Appendix B Frequently Asked Questions 296...
Страница 298: ...Appendix B Frequently Asked Questions 297...
Страница 299: ...Appendix B Frequently Asked Questions 298...
Страница 333: ...Revision history 332...