Fins Gateway Option
SECTION 6 Projects
85
It is possible to configure default settings for the runtime via the PLC Runtime
Default Settings fields in the Setup PLCs dialog box.
Communications to the PLC can be enabled on startup via the Open PLC
option.
6-8
Fins Gateway Option
CX-Supervisor normally uses the Omron CX-Server Communications
software for both device and point configuration, and also for runtime
communications (reading and writing values from a PLC).
Another Omron product, "Fins Gateway 2003", also provides communications
drivers that can be used for interfacing to Omron devices. Some users may
already have this software installed on their computers, and may prefer to use
it. In addition, a suitable Fins Gateway 2003 installer is supplied on the CX-
Supervisor CD.
The "Setup Devices" dialog box (shown below) contains the option for
configuring the system to use Fins Gateway instead of CX-Server. If the 'Use
Fins Gateway 2003' option is set, and Fins Gateway 2003 is present on a
computer, then the Fins Gateway drivers will automatically be used for runtime
communication to CS/CJ devices via Ethernet and Controller Link. CX-Server
will still be used for any non CS/CJ devices, and for any devices that don't use
either Ethernet or Controller Link. CX-Server is always used for configuring the
point data.
Note:
This is an advanced option. For most applications, communications via the
standard Omron CX-Server communications drivers is ideal, but in some
cases performance may be better or more consistent using the Omron Fins
Gateway 2003 drivers. This option allows the user to choose between the two
sets of drivers.
Содержание CX-Supervisor
Страница 1: ...CX Supervisor Software Cat No W10E EN 01 User Manual Software Release 3 1...
Страница 3: ...Copyright Notice 2...
Страница 16: ...15...
Страница 17: ...16...
Страница 27: ...Tip of the Day SECTION 1 Graphics Editor 26...
Страница 35: ...CX Supervisor Preferences SECTION 2 Pages 34...
Страница 79: ...Responding to Events SECTION 5 ActiveX Objects 78...
Страница 115: ...Printing the Graphics Library SECTION 7 Graphics Library 114...
Страница 181: ...Data Logging SECTION 11 Data Logging 180...
Страница 201: ...Examples SECTION 12 Databases 200...
Страница 243: ...Performance Monitor SECTION 16 Application Analysis Performance Monitor 242...
Страница 253: ...Using with Omron s CX Server OPC SECTION 17 Using CX Supervisor as an OPC Cli 252...
Страница 259: ...Creating a CX Supervisor Client application SECTION 18 Connecting to a remote CX 258...
Страница 263: ...Adding a Point Linked to a Parameter SECTION 19 Connecting to Omron Industrial 262...
Страница 271: ...Data Logging SECTION 20 Best Practices 270...
Страница 275: ...Configuring a Server PC running Windows NT or 2000 Appendix A Configuring a PC 274...
Страница 277: ...Appendix B Frequently Asked Questions 276...
Страница 296: ...Appendix B Frequently Asked Questions 295...
Страница 297: ...Appendix B Frequently Asked Questions 296...
Страница 298: ...Appendix B Frequently Asked Questions 297...
Страница 299: ...Appendix B Frequently Asked Questions 298...
Страница 333: ...Revision history 332...