Runtime Actions
SECTION 9 Animation
143
To specify a change in an object's colour, enter a Boolean expression in the
Digital Expression: field. Non-Boolean expressions may be entered as long as
the result is 'TRUE' or 'FALSE'.
The colours are specified in the Colour Attributes: fields for Boolean State 0
and Boolean State 1. To apply the change to the frame of the object, select the
Apply colour changes to object frame setting. To apply the change to the
object background, select the Apply colour changes to object background
setting.
On selection of a colour in the Colour Change (Digital) dialog box, the Colour
Palette dialog box opens. The Colour Palette dialog box is described in
chapter 9, Common Colour Palette.
To abort the Colour Change (Digital) edit, click the Cancel button. By clicking
the Browse button, a point may be directly specified, as described in chapter
9, Runtime Actions. When completed, click the OK button. If invalid data has
been inserted into any field, a descriptive error message opens.
9-3-17 Enable/Disable
Objects can be enabled or disabled. This is achieved using the Enable/Disable
dialog box.
To access the Enable/Disable dialog box to add an action, select Enable/
Disable from the animation list and click the Add Action button. To access the
Enable/Disable dialog box to modify an action, select Enable/Disable from the
animation list and click the Modify Action button. For a list of the objects to
which this action is applicable refer to chapter 9, Objects.
On selection of the Enable/Disable action, the Enable/Disable dialog box
opens:
To specify a change in the enabled/disabled state of an object, enter a
Boolean expression in the Digital Expression: field. Non-Boolean expressions
may be entered as long as the result is 'TRUE' or 'FALSE'. Whether the object
is enabled or disabled when the expression is 'TRUE' is chosen with the
Enable/Disable State settings.
Содержание CX-Supervisor
Страница 1: ...CX Supervisor Software Cat No W10E EN 01 User Manual Software Release 3 1...
Страница 3: ...Copyright Notice 2...
Страница 16: ...15...
Страница 17: ...16...
Страница 27: ...Tip of the Day SECTION 1 Graphics Editor 26...
Страница 35: ...CX Supervisor Preferences SECTION 2 Pages 34...
Страница 79: ...Responding to Events SECTION 5 ActiveX Objects 78...
Страница 115: ...Printing the Graphics Library SECTION 7 Graphics Library 114...
Страница 181: ...Data Logging SECTION 11 Data Logging 180...
Страница 201: ...Examples SECTION 12 Databases 200...
Страница 243: ...Performance Monitor SECTION 16 Application Analysis Performance Monitor 242...
Страница 253: ...Using with Omron s CX Server OPC SECTION 17 Using CX Supervisor as an OPC Cli 252...
Страница 259: ...Creating a CX Supervisor Client application SECTION 18 Connecting to a remote CX 258...
Страница 263: ...Adding a Point Linked to a Parameter SECTION 19 Connecting to Omron Industrial 262...
Страница 271: ...Data Logging SECTION 20 Best Practices 270...
Страница 275: ...Configuring a Server PC running Windows NT or 2000 Appendix A Configuring a PC 274...
Страница 277: ...Appendix B Frequently Asked Questions 276...
Страница 296: ...Appendix B Frequently Asked Questions 295...
Страница 297: ...Appendix B Frequently Asked Questions 296...
Страница 298: ...Appendix B Frequently Asked Questions 297...
Страница 299: ...Appendix B Frequently Asked Questions 298...
Страница 333: ...Revision history 332...