Appendix B Frequently Asked Questions
289
Boolean expressions can easily written to operate on bits within a word
e.g. nFlags & 0x02 will be TRUE if bit 2 is set or FALSE if it not. This
eliminates the need for additional memory points and processing.
•
Can I use token disks with USB Floppy drives or in high capacity
LS120 Disk Drives?
The token copy protection is no longer supported. The software tokens
have proven to be incompatible with some USB floppy drives and the high
capacity LS120 Disk Drives. If you need to remove a software token use
the network to conduct the token transfer, by sharing a floppy drive from
another machine.
•
Can I print accented characters on alarm printers?
There is a limitation with Windows, such that it is not possible to print
accented characters to a line printer a line at a time. The only alternatives
are:
•
To print using English only characters.
•
To set the printing to page mode, which will print a page when a
specified number of alarms have occurred. This can be set up under
Runtime settings, Alarm/Message printer settings.
•
Why do I get installation error - 115?
Error -115 during installation means the specified file could not be copied.
This is most often caused by the file already being in use or locked.
Reboot the machine, and attempt installing before running any Omron
software.
This error can also appear when attempting to install on a operating
system that does not support extended European characters, e.g.
Japanese or Chinese Windows. During installation, on the 'Select
Components' dialog box, select 'CX-Supervisor package' and click
'Change…'. Scroll to the bottom of the list of sub-components, and
deselect 'Language Files'. This will prevent language files, including those
using extended European characters being installed.
•
How do I address extended memory banks in PLCs?
In the point editor where you configure the PLC address, enter a hyphen
and the bank number for example:
E32000-3
Or (depending on PLC type)
EM32000-3
This will address memory location 32000 in bank 3.
•
Why can’t I see all my installed controls in the Insert Object dialog
box?
Under Windows 2000 and Windows XP the Insert Object dialog box is not
able to see all the controls installed on the PC. These include the MS
Forms 2.0 controls that are installed as part of MS Office.
Содержание CX-Supervisor
Страница 1: ...CX Supervisor Software Cat No W10E EN 01 User Manual Software Release 3 1...
Страница 3: ...Copyright Notice 2...
Страница 16: ...15...
Страница 17: ...16...
Страница 27: ...Tip of the Day SECTION 1 Graphics Editor 26...
Страница 35: ...CX Supervisor Preferences SECTION 2 Pages 34...
Страница 79: ...Responding to Events SECTION 5 ActiveX Objects 78...
Страница 115: ...Printing the Graphics Library SECTION 7 Graphics Library 114...
Страница 181: ...Data Logging SECTION 11 Data Logging 180...
Страница 201: ...Examples SECTION 12 Databases 200...
Страница 243: ...Performance Monitor SECTION 16 Application Analysis Performance Monitor 242...
Страница 253: ...Using with Omron s CX Server OPC SECTION 17 Using CX Supervisor as an OPC Cli 252...
Страница 259: ...Creating a CX Supervisor Client application SECTION 18 Connecting to a remote CX 258...
Страница 263: ...Adding a Point Linked to a Parameter SECTION 19 Connecting to Omron Industrial 262...
Страница 271: ...Data Logging SECTION 20 Best Practices 270...
Страница 275: ...Configuring a Server PC running Windows NT or 2000 Appendix A Configuring a PC 274...
Страница 277: ...Appendix B Frequently Asked Questions 276...
Страница 296: ...Appendix B Frequently Asked Questions 295...
Страница 297: ...Appendix B Frequently Asked Questions 296...
Страница 298: ...Appendix B Frequently Asked Questions 297...
Страница 299: ...Appendix B Frequently Asked Questions 298...
Страница 333: ...Revision history 332...