Appendix D CX-Server Error Codes
306
0xnn12
The device or function is locked by another user or application.
0xnn13
The name specified does not exist or cannot be found.
0xnn14
The specified PLC name does not exist.
0xnn15
The specified Project cannot be found or created.
0xnn16
The operation cannot be performed as the correct access
permissions have not be obtained. This usually indicates
another host currently has the PLC access rights.
0xnn17
The function or CDMPLCCommand is not supported in this
version of CX-Server.
0xnn18
The PLC could not be opened or the operation failed because
the PLC is open for communications. Check the communication
settings and that another application is not currently using the
connection method e.g Mouse configured and using COM1
port.
0xnn19
The Point could not be opened or the operation failed because
the Point is open for communications.
0xnn1A
Attempt to delete a currently selected User.
0xnn1B
Communications to the device could not be established or the
connection has been broken. Check the communication
settings and connection method to the device.
0xnn1C
An executing command was aborted by the execution of
another command or action.
0xnn1D
CX-Server is currently processing the maximum number of
requests. This error indicates the application is thrashing the
maximum possible communications throughput of the device's
connection.
0xnn1E
CX-Server has reached the maximum limitation for the
specified function.
0xnn1F
Communications Error occurred because of a Network Routing
Table problem. Check the routing tables in all devices are
correctly configured. In Alpha C series PLC's ensure the 'Allow
Routing Table' flag is set.
0xnn20
The specified Point name or key is invalid.
0xnn21
Device setup information or settings configuration is incorrect.
0xnn22
Device configuration information or data is incorrect.
0xnn23
The Unit number specified is invalid or does not exist.
0xnn24
The data cannot be converted to BCD as it contains
Hexadecimal values between 0xA and 0xF
Code
Cause
Содержание CX-Supervisor
Страница 1: ...CX Supervisor Software Cat No W10E EN 01 User Manual Software Release 3 1...
Страница 3: ...Copyright Notice 2...
Страница 16: ...15...
Страница 17: ...16...
Страница 27: ...Tip of the Day SECTION 1 Graphics Editor 26...
Страница 35: ...CX Supervisor Preferences SECTION 2 Pages 34...
Страница 79: ...Responding to Events SECTION 5 ActiveX Objects 78...
Страница 115: ...Printing the Graphics Library SECTION 7 Graphics Library 114...
Страница 181: ...Data Logging SECTION 11 Data Logging 180...
Страница 201: ...Examples SECTION 12 Databases 200...
Страница 243: ...Performance Monitor SECTION 16 Application Analysis Performance Monitor 242...
Страница 253: ...Using with Omron s CX Server OPC SECTION 17 Using CX Supervisor as an OPC Cli 252...
Страница 259: ...Creating a CX Supervisor Client application SECTION 18 Connecting to a remote CX 258...
Страница 263: ...Adding a Point Linked to a Parameter SECTION 19 Connecting to Omron Industrial 262...
Страница 271: ...Data Logging SECTION 20 Best Practices 270...
Страница 275: ...Configuring a Server PC running Windows NT or 2000 Appendix A Configuring a PC 274...
Страница 277: ...Appendix B Frequently Asked Questions 276...
Страница 296: ...Appendix B Frequently Asked Questions 295...
Страница 297: ...Appendix B Frequently Asked Questions 296...
Страница 298: ...Appendix B Frequently Asked Questions 297...
Страница 299: ...Appendix B Frequently Asked Questions 298...
Страница 333: ...Revision history 332...