6-10-2-9 Point Substitution Settings
The enclosing characters associated with a report can be changed via the
Point Substitution Settings dialog box. When set, these characters must be
fixed for all reports generated by the project. Select
Runtime Settings
from
the
Projects
menu, followed by
Point Substitution Settings
, the Point
Substitution Settings dialog box opens.
Supply enclosing characters in the Opening Characters: field and Closing
Characters: field. Click the
OK
button to accept the settings, or the Cancel
button to abort the operation.
6-10-2-10Advanced Settings
To open the Advanced Settings dialog box select Advanced Settings from the
Runtime Settings
menu:
Click the settings to enable/disable Internal Communication Optimisations and
Communication 'Packet' Optimisations.
Bad Quality values, and results of calculations using bad quality values can be
shown as '#' characters. This could indicate a communication failure, or Bad
Quality status in an OPC Server.
If you may need to option to edit the PLC settings in the runtime without
recompiling in the developer then untick the "Embed CX-Server Project within
CX-Supervisor .SR2 file" option. This is useful for example if it is possible the
Содержание CX-Supervisor
Страница 1: ...CX Supervisor Software Cat No W10E EN 01 User Manual Software Release 3 1...
Страница 3: ...Copyright Notice 2...
Страница 16: ...15...
Страница 17: ...16...
Страница 27: ...Tip of the Day SECTION 1 Graphics Editor 26...
Страница 35: ...CX Supervisor Preferences SECTION 2 Pages 34...
Страница 79: ...Responding to Events SECTION 5 ActiveX Objects 78...
Страница 115: ...Printing the Graphics Library SECTION 7 Graphics Library 114...
Страница 181: ...Data Logging SECTION 11 Data Logging 180...
Страница 201: ...Examples SECTION 12 Databases 200...
Страница 243: ...Performance Monitor SECTION 16 Application Analysis Performance Monitor 242...
Страница 253: ...Using with Omron s CX Server OPC SECTION 17 Using CX Supervisor as an OPC Cli 252...
Страница 259: ...Creating a CX Supervisor Client application SECTION 18 Connecting to a remote CX 258...
Страница 263: ...Adding a Point Linked to a Parameter SECTION 19 Connecting to Omron Industrial 262...
Страница 271: ...Data Logging SECTION 20 Best Practices 270...
Страница 275: ...Configuring a Server PC running Windows NT or 2000 Appendix A Configuring a PC 274...
Страница 277: ...Appendix B Frequently Asked Questions 276...
Страница 296: ...Appendix B Frequently Asked Questions 295...
Страница 297: ...Appendix B Frequently Asked Questions 296...
Страница 298: ...Appendix B Frequently Asked Questions 297...
Страница 299: ...Appendix B Frequently Asked Questions 298...
Страница 333: ...Revision history 332...