CHAPTER 11 FCAN CONTROLLER
611
User’s Manual U14492EJ3V0UD
Figure 11-38. CAN Message Control Registers 00 to 31 (M_CTRL00 to M_CTRL31) Settings
START
Yes
No
No
RTR = 0
RTR = 1
Transmit/receive remote frame
Transmit/receive
data frame?
Set remote frame auto
acknowledge function
Yes
No
IE = 0
IE = 1
Enable interrupt
Disable interrupt?
Yes
No
RMDE0 = 1
RMDE0 = 0
Remote frame auto
acknowledge?
Yes
No
RMDE1 = 1
RMDE1 = 0
ATS = 1
ATS = 0
Set DN flag?
Yes
Apply time stamp?
Set DN flag when remote
frame is received
Содержание V850E/IA1 mPD703116