(5) Full-scale error
This shows the difference between the actual measurement value of the analog input voltage and the
theoretical value (full scale
−
3/2LSB) when the digital output changes from 1……110 to 1……111.
Figure 13-19. Full-Scale Error
100
011
010
000
–0
AV
REFn
AV
REFn
–1
AV
REFn
–2
AV
REFn
–3
Digital output (Lo
w
er 3 bits)
Analog input (LSB)
Full-scale error
111
(n = 0, 1)
(6) Differential linearity error
While the ideal width of code output is 1LSB, this indicates the difference between the actual measurement
value and the ideal value.
Figure 13-20. Differential Linearity Error
0
AV
REFn
(n = 0, 1)
Digital output
Analog input
Differential
linearity error
1……1
0……0
Ideal 1LSB width