CHAPTER 9 TIMER/COUNTER FUNCTION (REAL-TIME PULSE UNIT)
332
User’s Manual U14492EJ3V0UD
(3) Transfer operation
The internal operation during TM1n transfer operation is as follows.
Figure 9-59. Internal Operation During Transfer Operation
Count clock
(rising edge set as valid edge)
CM1n0
0001H
Transfer operation is performed.
(Transfer operation is not performed.)
TM1n
0000H
FFFFH
(0001H)
FFFEH
(0002H)
FFFFH
Down count
Down count
(Up count)
Caution
The count operations after the TM1n count value becomes 0000H are as follows.
••••
In case of down count: Transfer operation is performed.
••••
In case of up count: Transfer operation is not performed.
Remarks 1.
n = 0, 1
2.
Items between parentheses in the above figure apply to up count operation.