CHAPTER 13 A/D CONVERTER
656
User’s Manual U14492EJ3V0UD
(5) A/D internal trigger selection register (ITRG0)
The ITRG0 register is the register that switches the trigger source in timer trigger mode. The timer trigger
source of A/D converters 0 and 1 can be set using the ITRG0 register.
This register can be read/written in 8-bit or 1-bit units.
7
0
ITRG0
6
ITRG22
5
ITRG21
4
ITRG20
3
0
2
ITRG12
1
ITRG11
0
ITRG10
Address
FFFFF280H
Initial value
00H
Bit Position
Bit Name
Function
Sets timer trigger source of A/D converter 1.
ITRG22
ITRG21
ITRG20
ITRG10
Trigger Source
0
0
×
0
Select INTCM003
0
0
×
1
Select INTCM013
0
1
0
×
Select INTTM00
0
1
1
×
Select INTTM01
1
×
0
0
Select INTCM003 and INTTM00
1
×
0
1
Select INTCM013 and INTTM00
1
×
1
0
Select INTCM003 and INTTM01
1
×
1
1
Select INTCM013 and INTTM01
6 to 4
ITRG22 to
ITRG20
Remark
×
: Arbitrary
Specifies timer trigger source of A/D converter 0.
ITRG12
ITRG11
ITRG20
ITRG10
Trigger Source
0
0
×
0
Select INTCM003
0
0
×
1
Select INTCM013
0
1
0
×
Select INTTM00
0
1
1
×
Select INTTM01
1
×
0
0
Select INTCM003 and INTTM00
1
×
0
1
Select INTCM013 and INTTM00
1
×
1
0
Select INTCM003 and INTTM01
1
×
1
1
Select INTCM013 and INTTM01
2 to 0
ITRG12 to
ITRG10
Remark
×
: Arbitrary
Содержание V850E/IA1 mPD703116