75
8.
Reduce the wheel brake pressure to 10 psi
after turning the switch off. At this time you
can discontinue using the brake pedal to
control the bagger movement.
9.
Monitor the stretch bars on the bag, do not
allow the bag to stretch beyond the bag
manufacturers recommendations.
10. Increase/decrease the brake pressure
at the wheels or increase/decrease the
amount of cable fed out as needed to cre-
ate a smooth bag. More cable fed out will
increase the drag/pressure on the anchors.
Watch the System Monitor display to
monitor the anchor pressure. The pressure
should be maintained between 1000 psi
and 1500 psi. These pressures will vary
depending on the moisture of the product
being bagged. It is important that you con-
tinually monitor the pressure and remain in
the range specified.
IMPORTANT: Do not allow anchor pressure
to exceed 1600 psi at any time. Anchors may
not retract if pressure exceeds 1600 psi.
Anchor Indicator
Indicator In Feet
Filling The Bag
When filling the bag, watch the System Monitor
display for all important settings and pressures
as the bag is being filled.
For all controls that follow, refer to the “Features
and Controls” section “In Cab Controls” for a
detailed explanation.
1.
Set the brake pressure at the engine and
cab side brakes to 20 psi using the brake
pressure switches on the right front cab
post. Watch the System Monitor display for
the brake pressure at each end.
2.
Use the brake pedal to control the move-
ment of the bagger when starting a new
bag. Apply pressure to the brakes as
needed.
3.
Chec
k the anchor float switch on the right
side console to make sure it is in the off
position.
4.
Start moving product into the bag.
5.
Start the inoculant applicator after product
has started into the bag. Shut off the in-
oculant applicator anytime the product has
stopped moving into the bag.
6.
Monitor the loads placed into the bag.
When you have bagged between 15 to 25
tons of product, turn the anchor float switch
on.
7.
Watch the anchor indicator just outside
the cab windshield. When the anchors are
out 5 feet (indicator pointing to 5), turn off
anchor float and watch anchor pressure on
System Monitor. If anchor pressure stabi-
lizes below 1000 psi, actuate anchor float
switch again to allow anchors to extend an
additional foot. Turn off anchor float and
check anchor pressure. Repeat this pro-
cedure until anchor pressure stabilizes at
1000 to 1500 psi. This setting will depend
on conditions of the crop, the wetter the
crop the less amount of cable should be
fed out.
Содержание AG-BAG Professional LX1214
Страница 20: ...14 Safety Sign and Decal Locations...
Страница 21: ...15 Safety Sign and Decal Locations continued...
Страница 128: ...122 Maintenance Record Date Service Performed...
Страница 129: ...123 Date Service Performed...
Страница 130: ...124 Date Service Performed...
Страница 158: ...2014 by Miller St Nazianz Inc...