143
Change feed table planetary oil as follows:
The feed table must be lowered down to the op-
erating position to drain the oil or to check level.
1. Locate the drain plug on the bottom of the
planetary. Clean around the drain plug and
remove.
2. Drain the oil into a suitable container. Re-
place the level plug after all the oil has
drained. Dispose of the used oil properly.
3. Remove the breather hose from the level
hole. Fill the planetary to the bottom of the
breather hose hole with synthetic 80W-140
gear lube oil.
4. Reassemble the breather hose to the plan-
etary and tighten securely.
5. Locate the feed table planetary breather
under the front of the cab floor. Be sure the
breather is clean.
Feed Table Planetary Level Check
Feed Table Planetary Drain Plug
Feed Table Planetary Breather
Breather
Breather Hose
Level Port
Drain Plug