96
SPN # FMI # Cummins
Fault #
Lamp Color Reason For Fault
Effect If Fault Is Active
Course Of Action
110
0
151
Red
Engine Coolant Tem-
perature - Data Valid But
Above Normal Operating
Range - Most Severe
Level. Intake Manifold
Air Temperature Signal
Indicates Intake Manifold
Air Temperature Above
Engine Protection Critical
Limit.
Progressive Power De-
rate Increasing In Sever-
ity From Time Of Alert
Check Coolant
Level. Check For
Restricted Air Flow
Through Radia-
tor. Call Cummins
Service.
111
1
235
Red
Coolant Level Signal At
Pin 22 Of The Sensor
Harness Indicates Cool-
ant Level Is Below The
Normal Range
Progressive Power De-
rate Increasing In Sever-
ity From Time Of Alert
Check Coolant
Level. Call Cummins
Service.
111
2
422
Yellow
Voltage Detected Simu-
latneously On Both The
Coolant High And Low
Signal Circuits Or No
Voltage Detected On
Both Circuits
No Engine Protection For
Coolant Level
Check Coolant
Level Wire Harness
For Shorts Or Open
Circuits. Call Cium-
mins Service.
157
3
451
Yellow
High Voltage Detected On
The Front Rail Pressure
Sensor Circuit
Engine Will Run Derated
Call Cummins
Service
157
4
452
Yellow
Low Voltage Detected On
The Front Rail Pressure
Sensor Circuit
Engine Will Run Derated
Call Cummins
Service
157
16
553
Yellow
Unexpectedly High Rail
Pressure Was Detected
On The Three Front
Cylinders
Engine Will Return To Idle
Speed, Then Only Idle Or
Shut Down
Call Cummins
Service
157
18
559
Yellow
Unexpectedly Low Rail
Pressure Was Detected
On The Three Front
Cylinders
Low Power Or Rough Idle
Call Cummins
Service
157
7
755
Yellow
Incorrect Fueling Was
Detected On The Front
Three Cylinders
Engine Will Misfire
Check For Fuel
Return Line Restric-
tion. Check For Air
In Fuel. Call Cum-
mins Service.
166
2
951
None
A Power Imbalance Was
Detected By The Ecm
Engine Can Have A
Rough Idle Or Misfire
Call Cummins
Service
167
16
596
Yellow
High Battery Voltage
Detected By The Battery
Voltage Monitor Feature
Yellow Lamp Will Be Lit
Until High Battery Voltage
Condition Is Corrected
Check Alternator
And Battery Con-
nections. Call Cum-
mins Service
167
18
597
Yellow
Low Battery Voltage
Detected By The Battery
Voltage Monitor Feature
Yellow Lamp Will Be Lit
Until High Battery Voltage
Condition Is Corrected
Check Alternator
And Battery Con-
nections. Call Cum-
mins Service
Содержание AG-BAG Professional LX1214
Страница 20: ...14 Safety Sign and Decal Locations...
Страница 21: ...15 Safety Sign and Decal Locations continued...
Страница 128: ...122 Maintenance Record Date Service Performed...
Страница 129: ...123 Date Service Performed...
Страница 130: ...124 Date Service Performed...
Страница 158: ...2014 by Miller St Nazianz Inc...