3
KHA3000
59
Connecting a Voltmeter to External Measurement Points
W
iring M
easurem
ent Circuits
Three-phase four-wire circuit
Using PT (potential transformer)
When the voltage of the device to be measured exceeds the maximum voltage range of this
product, a PT (potential transformer) may be connected. The connection circuit is shown for
single-phase, two-wire circuits. For other circuits, similarly connect a PT for each phase.
When a PT is used, it is necessary to set the scaling that corresponds to the transformer
ratio.
A
V
A
V
A
V
U
V
W
N
N
G
G
U
V
V
W
N
G
L1
L2
L3
±
V
±
V
±
SOURCE
LOAD
KHA3000
EUT
See
A
V
L1
N
N
G
G
L
V
N
G
L1
SOURCE
LOAD
KHA3000
EUT
PT(potential
transformer)
Содержание KHA3000
Страница 20: ...20 KHA3000...
Страница 35: ...Overview This chapter provides an overview of this product and explains the options for the product 1...
Страница 42: ...42 KHA3000 Options...
Страница 49: ...Wiring Measurement Circuits This chapter explains the wiring of measurement circuits and the control circuit 3...
Страница 70: ...70 KHA3000 Connecting Communication Cables...
Страница 71: ...System Setup This chapter explains how to turn on the power and how to set up the system 4...
Страница 91: ...Setting the Harmonic Test This chapter explains how to set the test conditions for the harmonic current test 5...
Страница 120: ...120 KHA3000 Controlling the AC Power Supply...
Страница 182: ...182 KHA3000 Checking the AC Power Supply and Repeatability...
Страница 247: ...Other Measurements This chapter explains basic measurement FFT analyzer and in rush current measurement 11...
Страница 349: ...Maintenance This chapter explains how to clean and inspect this product 14...
Страница 352: ...352 KHA3000 Cleaning and Checking...
Страница 353: ...Specifications This chapter explains the specifications of this product 15...
Страница 390: ...390 KHA3000...
Страница 391: ......