10
KHA3000
245
View Setting Sub-menu
O
bs
er
va
tio
n,
A
na
ly
si
s
an
d
Ju
dg
em
en
t o
f V
ol
ta
ge
F
lu
ct
ua
tio
ns
61000-3-3 (Manual)
●
General judgment and judgment of conformance to the standards
●
Test data and judgment
Item
Description
Result
General judgment (PASS/FAIL/WARN)
Displays WARN if the margin is exceeded.
Displays ABORT if the test is aborted.
*1
*1.
The test is aborted when a measured value exceeds the voltage or current range,
synchronization of PLL fails, or overheating of the current detecting portion is detected.
dMargin
Margin in relation to the limit values of dc, dmax and Tmax
*2
*2.
Displayed as d(t)>3.3% depending on the selected standard.
Item
Seg
dmax[%]
dc[%]
Tmax
*1
[ms]
Limit
Limit value
Description The d
measurement
time corresponds
to one segment
(Seg1 or any
later segment)
time.
dmax (%) value
of all segment
(Seg1 and
subsequent
segments) time
(set in d
Measurement
Count)
dc(%) value of all
segment (Seg1
and subsequence
segments) times
(set in d
Measurement
Count)
Tmax
*1
time (ms)
of all segment
(Seg1 and
subsequence
segments) times
(set in d
Measurement
Count)
Item
dmax[%]
Item
dc[%]
Tmax
*1
[ms]
*1.
Displayed as d(t)>3.3% depending on the selected standard.
Judge
Limit
Limit value
Limit
Limit value
Limit value
Target phase
Average
Average of
measured values
excluding the
maximum and
minimum values
Maximum Maximum
value
Maximum
value
Judgment
according to limit
values
Содержание KHA3000
Страница 20: ...20 KHA3000...
Страница 35: ...Overview This chapter provides an overview of this product and explains the options for the product 1...
Страница 42: ...42 KHA3000 Options...
Страница 49: ...Wiring Measurement Circuits This chapter explains the wiring of measurement circuits and the control circuit 3...
Страница 70: ...70 KHA3000 Connecting Communication Cables...
Страница 71: ...System Setup This chapter explains how to turn on the power and how to set up the system 4...
Страница 91: ...Setting the Harmonic Test This chapter explains how to set the test conditions for the harmonic current test 5...
Страница 120: ...120 KHA3000 Controlling the AC Power Supply...
Страница 182: ...182 KHA3000 Checking the AC Power Supply and Repeatability...
Страница 247: ...Other Measurements This chapter explains basic measurement FFT analyzer and in rush current measurement 11...
Страница 349: ...Maintenance This chapter explains how to clean and inspect this product 14...
Страница 352: ...352 KHA3000 Cleaning and Checking...
Страница 353: ...Specifications This chapter explains the specifications of this product 15...
Страница 390: ...390 KHA3000...
Страница 391: ......