Observation, Analysis and Judgem
ent of Harm
onics
Displaying the HA-Observation and Analysis
Display (HA-VIEW)
Displaying the HA-Observation and Analysis Display (Switching
Displays)
1
Press the HA key.
The HA key LED illuminates and the HA-Test Conditions List display appears.
2
Press the VIEW key in the HA-Test Conditions List display.
The VIEW key LED illuminates and the HA-Observation and Analysis display (HA-
VIEW) appears.
3
Press the VIEW key again.
The screen switches between the HA-Observation and Analysis display (HA-VIEW) and
HA-Observation and Test Conditions display (toggle operation).
If the display does not appear by pressing the HA key
A dialog box
“
Can
’
t execute during test/analysis. Please operate it after ending
”
is displayed
and the display switches to the test ending menu.
While the test status display (in the upper left of the screen,
“
Set
”
in the case of the
figure shown above) is
“
Test
”
or
“
Analysis,
”
pressing the HA key does not display the
HA-Test Conditions List display. Because displaying the HA-Test Conditions List display
starts a new test with the test conditions changed, the test that has been executed
needs to be terminated.
4
Press the F3 key (Exit) in the test ending menu.
The test ends. The test status display on the screen switches from
“
Analysis
”
to
“
Set.
”
If
the test results have not been saved with the F1 key (Save), a dialog box and a menu
for saving operation appear. To save the test results, select F1 (Yes); otherwise, select
F2 (No).
5
Press the HA key.
The HA key LED illuminates and the HA-Test Conditions List display appears.
6
Press the View key.
The VIEW key LED illuminates and the HA-Observation and Analysis display (HA-
VIEW) appears.
See
Содержание KHA3000
Страница 20: ...20 KHA3000...
Страница 35: ...Overview This chapter provides an overview of this product and explains the options for the product 1...
Страница 42: ...42 KHA3000 Options...
Страница 49: ...Wiring Measurement Circuits This chapter explains the wiring of measurement circuits and the control circuit 3...
Страница 70: ...70 KHA3000 Connecting Communication Cables...
Страница 71: ...System Setup This chapter explains how to turn on the power and how to set up the system 4...
Страница 91: ...Setting the Harmonic Test This chapter explains how to set the test conditions for the harmonic current test 5...
Страница 120: ...120 KHA3000 Controlling the AC Power Supply...
Страница 182: ...182 KHA3000 Checking the AC Power Supply and Repeatability...
Страница 247: ...Other Measurements This chapter explains basic measurement FFT analyzer and in rush current measurement 11...
Страница 349: ...Maintenance This chapter explains how to clean and inspect this product 14...
Страница 352: ...352 KHA3000 Cleaning and Checking...
Страница 353: ...Specifications This chapter explains the specifications of this product 15...
Страница 390: ...390 KHA3000...
Страница 391: ......