Checking the AC Power Supply and Repeatability
Checking the AC Power Supply
Use this menu to check the performance of the AC power supply (voltage, voltage distortion
factor and frequency). Check the performance using the LOAD terminal of this product. When
the test conditions are set before the test is executed, judgment (PASS/FAIL) is made by real-
time measurement. After the test is executed, judgment (PASS/FAIL) is made from in-test
measurement values.
When the connection cable to the EUT is long, standard requirements may not be satisfied
because of an increase in voltage drop and inductance.
●
Operation when the following standards are selected and operation of this product
•
IEC 61000-3-2 standard
Jjudgment (PASS/FAIL) is made from the measurement values after the test.
•
JIS 61000-3-2 2005 standard (Using reference impedance), JIS 61000-3-2 2019
standard (Using reference impedance) or IEC 61000-3-12 standard
Before starting the test, remove the equipment under test (EUT) and check the
AC power source.
Press the F2 (Record) key to record the measured values. If you do not record
the values, when you set Select View Items to Measured Values, the correct
values will not be displayed.
After the test starts, the recorded values will be displayed.
Explanation of display items
Item
Description
Volt
Effective value of voltage (V)
Curr
Effective value of current (A)
Peak+
Positive peak voltage (V)
Peak-
Negative peak voltage (V)
Freq
Frequency (Hz)
Result
Result of the general judgment (PASS/FAIL)
Содержание KHA3000
Страница 20: ...20 KHA3000...
Страница 35: ...Overview This chapter provides an overview of this product and explains the options for the product 1...
Страница 42: ...42 KHA3000 Options...
Страница 49: ...Wiring Measurement Circuits This chapter explains the wiring of measurement circuits and the control circuit 3...
Страница 70: ...70 KHA3000 Connecting Communication Cables...
Страница 71: ...System Setup This chapter explains how to turn on the power and how to set up the system 4...
Страница 91: ...Setting the Harmonic Test This chapter explains how to set the test conditions for the harmonic current test 5...
Страница 120: ...120 KHA3000 Controlling the AC Power Supply...
Страница 182: ...182 KHA3000 Checking the AC Power Supply and Repeatability...
Страница 247: ...Other Measurements This chapter explains basic measurement FFT analyzer and in rush current measurement 11...
Страница 349: ...Maintenance This chapter explains how to clean and inspect this product 14...
Страница 352: ...352 KHA3000 Cleaning and Checking...
Страница 353: ...Specifications This chapter explains the specifications of this product 15...
Страница 390: ...390 KHA3000...
Страница 391: ......