2
KHA3000
47
Installation and Preparation for Use
Connecting Power Cord
This product is an equipment of IEC Overvoltage Category II (energy-consuming equipment
supplied from the fixed installation).
1
Turn off the POWER switch.
2
Check that the AC power line to be
connected conforms to the input
ratings of this product.
The voltage that can be input is a nominal
power supply voltage ranging from 100 Vac to
240 Vac, and the frequency is 50 or 60 Hz.
3
Connect the power cord to the AC
inlet (AC INPUT) on the rear panel.
4
Connect the power cord plug to an
outlet with a grounding electrode.
Connecting the Input Power Supply of the Test System
This section explains how to use this product, AC Power Supply, and the Line Impedance
Network for a test system. To turn on and off the power switches altogether in the test system,
use an external power switch separately.
AC Power Supply
Connect the INPUT terminals of the AC Power Supply and the terminals on the switchboard.
A person qualified for electrical work should make the connections. For more information,
refer to the Operation Manual of the AC Power Supply.
WARNING
•
This product is an IEC Safety Class I equipment (equipment with a protective
conductor terminal). To prevent an electric shock, be sure to ground it.
•
This product is grounded through the grounding wire of the power cord. Be sure to
connect the power plug to an outlet with an appropriate earth ground.
•
To connect to the AC power line, use the accessory power cord.
If the accessory power cord cannot be used because of its rated voltage or plug shape,
have a qualified engineer replace it with an appropriate power cord of 3 m or shorter. If it is
difficult to procure the power cord, contact your Kikusui distributor or agent.
•
A power cord with a plug can be used to disconnect this product from the AC power line in
an emergency. To disconnect the plug from the outlet at any time, connect the plug to an
outlet within your reach and keep sufficient space around the outlet.
•
Do not use the accessory power cord to operate another device.
An outlet with a grounding
electrode where grounding
is provided
Содержание KHA3000
Страница 20: ...20 KHA3000...
Страница 35: ...Overview This chapter provides an overview of this product and explains the options for the product 1...
Страница 42: ...42 KHA3000 Options...
Страница 49: ...Wiring Measurement Circuits This chapter explains the wiring of measurement circuits and the control circuit 3...
Страница 70: ...70 KHA3000 Connecting Communication Cables...
Страница 71: ...System Setup This chapter explains how to turn on the power and how to set up the system 4...
Страница 91: ...Setting the Harmonic Test This chapter explains how to set the test conditions for the harmonic current test 5...
Страница 120: ...120 KHA3000 Controlling the AC Power Supply...
Страница 182: ...182 KHA3000 Checking the AC Power Supply and Repeatability...
Страница 247: ...Other Measurements This chapter explains basic measurement FFT analyzer and in rush current measurement 11...
Страница 349: ...Maintenance This chapter explains how to clean and inspect this product 14...
Страница 352: ...352 KHA3000 Cleaning and Checking...
Страница 353: ...Specifications This chapter explains the specifications of this product 15...
Страница 390: ...390 KHA3000...
Страница 391: ......