61000-3-12 2004: Test Flow
Executing Harm
onic Tests
Test execution
AC power
supply check
and record
Rsce estimation
Re-estimation of Rsce
Test execution
Is the
limit value
satisfied?
No
Yes
No
Yes
Minimum
Rsce value that
satisfies the
limit value
More than 33
33
Tables 2 and 3
Table 4
Comparison of
Rsce values
Applied
limit value
table
Requirements of power supply
Declare Ssc that corresponds
to the minimum Rsce value
that satisfies the limit value.
Conforms to 61000-3-12 2004
when short-circuit power upon connection
with the commercial power is equal to
or greater than the declared Ssc.
Apply the limit value table
(Table 4) of balanced
three-phase equipment with
specified conditions.
Conforms to
61000-3-12 2004.
The expression of each item is simplified. For details, refer to the standards.
Apply the limit value table
(Table 3) of balanced
three-phase equipment.
Set the impedance of
the power supply to at
least the estimated Rsce.
Set the impedance of the
power supply to at least
1.6 times the estimated
Rsce.
Apply the limit value table
(Table 2) of equipment other
than balanced three-phase.
Is the minimum Rsce value that
satisfiesthe limit value equal to or
less than the estimated Rsce?
Содержание KHA3000
Страница 20: ...20 KHA3000...
Страница 35: ...Overview This chapter provides an overview of this product and explains the options for the product 1...
Страница 42: ...42 KHA3000 Options...
Страница 49: ...Wiring Measurement Circuits This chapter explains the wiring of measurement circuits and the control circuit 3...
Страница 70: ...70 KHA3000 Connecting Communication Cables...
Страница 71: ...System Setup This chapter explains how to turn on the power and how to set up the system 4...
Страница 91: ...Setting the Harmonic Test This chapter explains how to set the test conditions for the harmonic current test 5...
Страница 120: ...120 KHA3000 Controlling the AC Power Supply...
Страница 182: ...182 KHA3000 Checking the AC Power Supply and Repeatability...
Страница 247: ...Other Measurements This chapter explains basic measurement FFT analyzer and in rush current measurement 11...
Страница 349: ...Maintenance This chapter explains how to clean and inspect this product 14...
Страница 352: ...352 KHA3000 Cleaning and Checking...
Страница 353: ...Specifications This chapter explains the specifications of this product 15...
Страница 390: ...390 KHA3000...
Страница 391: ......