6
KHA3000
149
Test Ending Menu
Executing Harm
onic Tests
Procedures for inputting a character (F1 key) and deleting a character (F2
key)
1
Press the F1, F2, F3 or F4 key.
The Comment Input dialog will be presented.
2
Use the small knob, large knob or arrow keys to select a character by
moving the rectangular frame.
3
Press the F1 (Input 1-char) key.
The character selected will be added to the part where the cursor is blinking (Input 1-
char). To delete a character, press the F2 (Delete 1-char) key. To change the character
type, press the F3 (Change char type) key to select the type. To repeat adding or
deleting characters, return to the above step 2.
4
Press the ENTER key.
The characters entered will be fixed and saved.
9
Return
Terminates the comment input.
–
10
Std. Name Select
Select how the "Limitation Std" and "Meas. Tech" names are
presented in Report Print. Selects either "Standard" or "Setting".
Standard
11
Input 1-char
This function is used to enter characters for the local Limitation
Standard name or the local Measuring technique name to be
presented in Report Print. Up to 20 alphanumeric characters can be
entered. On how to use this function, refer to the procedures shown
below.
–
12
Delete 1-char
This function is used to delete characters from the local Limitation
Standard names or the local Measuring technique names to be
presented in Report Print. On how to use this function, refer to the
procedures shown below.
–
13
Return
Exit from the character entry/deletion procedures to display local
Limitation Standard or local Measuring technique names.
–
14
Return
Exit from the setting of standard names to be presented.
–
15
Return
Terminates the report printing.
–
16
Exit
Terminates the test.
–
17
Analysis (VIEW)
Analyses test results.
–
18
AC Power Supply OUT-
PUT OFF
Turn off the output of the AC power supply. This item is displayed
when it is so set to control the AC power supply.
F key: Function key. You can also use the ESC key to return.
See
Содержание KHA3000
Страница 20: ...20 KHA3000...
Страница 35: ...Overview This chapter provides an overview of this product and explains the options for the product 1...
Страница 42: ...42 KHA3000 Options...
Страница 49: ...Wiring Measurement Circuits This chapter explains the wiring of measurement circuits and the control circuit 3...
Страница 70: ...70 KHA3000 Connecting Communication Cables...
Страница 71: ...System Setup This chapter explains how to turn on the power and how to set up the system 4...
Страница 91: ...Setting the Harmonic Test This chapter explains how to set the test conditions for the harmonic current test 5...
Страница 120: ...120 KHA3000 Controlling the AC Power Supply...
Страница 182: ...182 KHA3000 Checking the AC Power Supply and Repeatability...
Страница 247: ...Other Measurements This chapter explains basic measurement FFT analyzer and in rush current measurement 11...
Страница 349: ...Maintenance This chapter explains how to clean and inspect this product 14...
Страница 352: ...352 KHA3000 Cleaning and Checking...
Страница 353: ...Specifications This chapter explains the specifications of this product 15...
Страница 390: ...390 KHA3000...
Страница 391: ......