KHA3000
Harmonic Measurement Mode (61000-3-2)
Class D Conditions
HARM:IEC32:POW:DEF
Sets the type of power value for Class D. The type and the default of the value vary
corresponding to the test standard.
Command
HARMonics:IEC32:POWer:DEFinition
{MEASured|SPECified}
HARMonics:IEC32:POWer:DEFinition?
Parameter Value:
MEASured
Measured value (default)
SPECified
Specified value
Response
Returns the type of power value in the <character> format.
HARM:IEC32:POW
Sets the specified value of the power.
Command
HARMonics:IEC32:POWer[:LEVel]{<numeric>|MIN|MAX}
HARMonics:IEC32:POWer[:LEVel]?
Parameter Value:
0 to 135000 (The default is 100.)
Unit:
W
Response
Returns the value specified for the power in the <NR3> format.
** RST
RST
** RST
RST
Содержание KHA3000
Страница 20: ...20 KHA3000...
Страница 35: ...Overview This chapter provides an overview of this product and explains the options for the product 1...
Страница 42: ...42 KHA3000 Options...
Страница 49: ...Wiring Measurement Circuits This chapter explains the wiring of measurement circuits and the control circuit 3...
Страница 70: ...70 KHA3000 Connecting Communication Cables...
Страница 71: ...System Setup This chapter explains how to turn on the power and how to set up the system 4...
Страница 91: ...Setting the Harmonic Test This chapter explains how to set the test conditions for the harmonic current test 5...
Страница 120: ...120 KHA3000 Controlling the AC Power Supply...
Страница 182: ...182 KHA3000 Checking the AC Power Supply and Repeatability...
Страница 247: ...Other Measurements This chapter explains basic measurement FFT analyzer and in rush current measurement 11...
Страница 349: ...Maintenance This chapter explains how to clean and inspect this product 14...
Страница 352: ...352 KHA3000 Cleaning and Checking...
Страница 353: ...Specifications This chapter explains the specifications of this product 15...
Страница 390: ...390 KHA3000...
Страница 391: ......