13
KHA3000
293
Measurements in General
Rem
ote Contr
ol
Parameter Value:
SHUNt
Internal shunt (default)
CLAMp
Clamp type current sensor
BNC
External signal input
Response
Returns the current input terminal setting in the <character> format.
INP:CURR:TERM:IND
Sets the current input terminals. Each input phase (channel) is set independently.
This command is enabled when the input circuit setting is
“
independent
”
(INP:LINK OFF).
Command
INPut:CURRent:TERMinal:IHDependent
<character>,<character>,<character>
INPut:CURRent:TERMinal:INDependent?
Parameter Value:
SHUNt
Internal shunt (default)
CLAMp
Clamp type current sensor
BNC
External signal input
Specify the <character> commands in the order of <L1 phase>, <L2 phase> and
<L3 phase>.
Response
Returns the current ranges in the <character>, <character>, <character> format. The
<character> responses are in the order of <L1 phase>, <L2 phase> and <L3 phase>.
Setting the PLL Source to Synchronize with the AC Power
Supply
INP:PLL:SOUR
Sets the PLL source to synchronize with the frequency of the AC power supply.
Voltage or current signal in each of the L1, L2 and L3 phases can be selected. Select EXT
when using the input signals of EXT SYNC INPUT.
Command
INPut:PLL:SOURce {CL1|CL2|CL3|VL1|VL2|VL3|EXT}
INPut:PLL:SOURce?
Parameter Value:
CL1, CL2, CL3
Current signals in L1, L2 and L3 phases
VL1, VL2, VL3
Voltage signals in L1(default), L2 and L3 phases
EXT
Input signal in EXT SYNC INPUT
Response
Returns the PLL source in the <character> format.
** RST
RST
** RST
RST
Содержание KHA3000
Страница 20: ...20 KHA3000...
Страница 35: ...Overview This chapter provides an overview of this product and explains the options for the product 1...
Страница 42: ...42 KHA3000 Options...
Страница 49: ...Wiring Measurement Circuits This chapter explains the wiring of measurement circuits and the control circuit 3...
Страница 70: ...70 KHA3000 Connecting Communication Cables...
Страница 71: ...System Setup This chapter explains how to turn on the power and how to set up the system 4...
Страница 91: ...Setting the Harmonic Test This chapter explains how to set the test conditions for the harmonic current test 5...
Страница 120: ...120 KHA3000 Controlling the AC Power Supply...
Страница 182: ...182 KHA3000 Checking the AC Power Supply and Repeatability...
Страница 247: ...Other Measurements This chapter explains basic measurement FFT analyzer and in rush current measurement 11...
Страница 349: ...Maintenance This chapter explains how to clean and inspect this product 14...
Страница 352: ...352 KHA3000 Cleaning and Checking...
Страница 353: ...Specifications This chapter explains the specifications of this product 15...
Страница 390: ...390 KHA3000...
Страница 391: ......