270
Jetter AG
10 Programming
Configuration - Register description
These registers can be used to check the SET configuration and the three
received ACTUAL configurations When you have entered the GNN in
MR 2000, the controller transfers the values to the 4 register arrays.
GNN
Enter the GNN here.
Module register properties
Values
1 ... 199
Value after reset
1
SET configuration
These registers let you read the default SET configuration.
Register
Command line parameter
2010
NodeID (GNN)
2011
CtrlID
2012
CtrlIDopt
2013
IpAddr
2014
IpMask
2015
Gateway
ACTUAL configuration 1
These registers let you read the first received ACTUAL configuration.
Register
Command line parameter
2110
NodeID (GNN)
2111
CtrlID
2112
CtrlIDopt
2113
IpAddr
2114
IpMask
2115
Gateway
2120
Quantity
2121
MAC address high
2122
MAC address low
Introduction
MR 2000
MR 2010 ... 2015
MR 2110 ... 2123
Содержание JC-120MC
Страница 1: ...User Manual JC 120MC Controller 60880901 We automate your success...
Страница 18: ......
Страница 40: ...40 Jetter AG 3 Identifying Hardware revisions see page 38 Related topics...
Страница 160: ......
Страница 186: ......
Страница 196: ......
Страница 395: ...Jetter AG 395 JC 120MC Programming Result When initializing the JX2 system bus the adjusted baud rate values were used...
Страница 485: ...Jetter AG 485 JC 120MC Programming Topic Page Programming 486 Registers 498 Contents...
Страница 521: ...Jetter AG 521 JC 120MC Programming Use 29 bit identifier Default 11 bit identifier...
Страница 586: ......
Страница 604: ......
Страница 633: ......