Mechanical and electrical installation
Interface cable KAY_0386-xxxx
The interface cable KAY_0386-xxxx lets you connect HMIs of the type LCD 60
to the JC-120MC.
For information on connector specification refer to the list below:
Type
8-pin male MiniDIN connector
Manufacturer
KYCON
Item
KMDLA - 8P
Recommended core cross section
0.128 … 0.051 mm
2
For information on female connector specification refer to the list below:
Type
15-pin female Sub-D connector in
metallized housing (quality grade 3).
Manufacturer
Various manufacturers
Recommended core cross section
0.25 … 0.128 mm
2
For information on cable specification refer to the list below:
Number of cores
5
Recommended core cross section
0.14 mm
2
Maximum cable length
400 m
Complete shielding, no paired shielding
The shield must be connected to the connector housings on both ends of
the cable with the greatest possible surface area.
Place the shield as follows:
•
Connect the shield by its greatest possible surface area.
•
Clamp it under a strain relief.
•
Wrap it with copper foil.
Introduction
Male connector
specification
(controller end)
Female connector
specification (HMI end)
Specifications of
connecting cable
Cable shielding
Содержание JC-120MC
Страница 1: ...User Manual JC 120MC Controller 60880901 We automate your success...
Страница 18: ......
Страница 40: ...40 Jetter AG 3 Identifying Hardware revisions see page 38 Related topics...
Страница 160: ......
Страница 186: ......
Страница 196: ......
Страница 395: ...Jetter AG 395 JC 120MC Programming Result When initializing the JX2 system bus the adjusted baud rate values were used...
Страница 485: ...Jetter AG 485 JC 120MC Programming Topic Page Programming 486 Registers 498 Contents...
Страница 521: ...Jetter AG 521 JC 120MC Programming Use 29 bit identifier Default 11 bit identifier...
Страница 586: ......
Страница 604: ......
Страница 633: ......