Jetter AG
229
JC-120MC
Programming
Command group NetBit()
The NetBit command is an all-purpose tool to set or clear register bits of Jetter
products. The Jetter products are interconnected via an Ethernet network.
NetBit commands let you both set and clear bits in one go.
Simulating NetBit commands by means of NetCopy commands:
A NetCopy command lets you copy the register value from the remote
node to the local controller.
A NetCopy command lets you change the state of the bits on the local
controller as desired.
Another NetCopy command lets you copy the register value to the remote
node again.
For this, several commands are required. Thus, a register value may be
changed during this action by an application program running on the remote
controller. The second NetCopy command will then overwrite this value again.
There is an undefined data condition, which is prevented by the NetBit
functions.
Further advantages of NetBit commands as compared with the use of network
registers:
Within the command, you can directly specify any valid IP address.
Within the command, you can directly specify any valid IP port.
The entire register address range of a remote node can be directly
addressed.
The result of executing this command can be evaluated directly.
NetBit functions with the following nodes:
Controllers
Bus node
Communication modules
To access other nodes, use the command NetBit as follows:
If ...
... then ...
you wish to set register bits for another
node,
use the command
NetBitSetReg
you wish to clear register bits of another
node,
use the command
NetBitClearReg
For detailed information on the parameters, refer to the JetSym help.
Introduction
Advantages of NetBit
Access via NetBit
Parameters of the NetBit
commands
Содержание JC-120MC
Страница 1: ...User Manual JC 120MC Controller 60880901 We automate your success...
Страница 18: ......
Страница 40: ...40 Jetter AG 3 Identifying Hardware revisions see page 38 Related topics...
Страница 160: ......
Страница 186: ......
Страница 196: ......
Страница 395: ...Jetter AG 395 JC 120MC Programming Result When initializing the JX2 system bus the adjusted baud rate values were used...
Страница 485: ...Jetter AG 485 JC 120MC Programming Topic Page Programming 486 Registers 498 Contents...
Страница 521: ...Jetter AG 521 JC 120MC Programming Use 29 bit identifier Default 11 bit identifier...
Страница 586: ......
Страница 604: ......
Страница 633: ......