![Jetter JC-120MC Скачать руководство пользователя страница 561](http://html1.mh-extra.com/html/jetter/jc-120mc/jc-120mc_user-manual_3870525561.webp)
Jetter AG
561
JC-120MC
Programming
Step
Action
1
Prompt sending an RTR frame from message box 0:
R 200010543 := 3;
2
Wait for a reply to the RTR frame in message box 1:
If ...
... then ...
... bit 1
NEW-DAT
= 1 in
R200010550,
... the controller has received the
reply to the RTR frame.
Proceed with step 3.
3
Read the number of received bytes
Number of bytes = R 200010553;
4
Read the received bytes
Data byte 0 = R 200010554;
Data byte 1 = R 200010555;
...
Data byte 7 = R 200010561;
5
Acknowledge reception
R 200010563 := 4;
The message box is again ready to receive.
Sending and receiving
RTR frames