Jetter AG
563
JC-120MC
Automatic copying of controller data
For automatic copying of controller data, the following prerequisites must be
fulfilled:
The programmer is familiar with the file system.
The programmer must have basic knowledge in the area of FTP
application.
This is an example of a configuration file
config.ini
with an entry
AutoCopyIni
.
;<Productname> System Configuration
;Copyright (c) 2009 by Jetter AG, Ludwigsburg, Germany
[IP]
Address = 192.168. 10.209
SubnetMask = 255.255.255. 0
DefGateway = 0. 0. 0. 0
DNSServer = 192.168. 10.244
[HOSTNAME]
SuffixType = 0
Name = JetControl120MC
[PORTS]
JetIPBase = 50000
JVMDebug = 52000
[FILES]
AutoCopyIni = /SD/project_name/autocopy.ini
The AutoCopy function only makes sense, if the data to be copied have
been stored to the SD card. This means that the root directory is
/SD/
.
Since operating system version OS Neue AutoCopy-Funktion of JC-120MC
the following applies:
The file
autocopy.ini
can be stored to any subdirectory.
Instead of
autocopy.ini
, you can name the file arbitrarily.
In this description,
Complete Name
means the name of the file or directory
including the complete path.
Topic
Page
Operating principle ..................................................................................... 564
autocopy.ini - Structure ............................................................................... 569
Log file ........................................................................................................ 582
Data files ..................................................................................................... 584
Prerequisites
config.ini - Example
AutoCopyIni - Note
Designation
Contents
Содержание JC-120MC
Страница 1: ...User Manual JC 120MC Controller 60880901 We automate your success...
Страница 18: ......
Страница 40: ...40 Jetter AG 3 Identifying Hardware revisions see page 38 Related topics...
Страница 160: ......
Страница 186: ......
Страница 196: ......
Страница 395: ...Jetter AG 395 JC 120MC Programming Result When initializing the JX2 system bus the adjusted baud rate values were used...
Страница 485: ...Jetter AG 485 JC 120MC Programming Topic Page Programming 486 Registers 498 Contents...
Страница 521: ...Jetter AG 521 JC 120MC Programming Use 29 bit identifier Default 11 bit identifier...
Страница 586: ......
Страница 604: ......
Страница 633: ......