608
Jetter AG
15 Quick reference - JC-120(MC)
200008
Error register 1 (identical with 210004)
Bit 0:
Error on flash disk
Bit 1:
Error on JX3 system bus
Bit 2:
Error on JX2 system bus
Bit 3:
Error on Ethernet system bus
Bit 7:
Error in expanded error register
Bit 8:
Illegal jump
Bit 9:
Illegal call
Bit 10:
Illegal index
Bit 11:
Illegal opcode
Bit 12:
Division by 0
Bit 13:
Stack overflow
Bit 14:
Stack underflow
Bit 15:
Illegal stack
Bit 16:
Error when loading the application program
Bit 17:
Memory protection violated
Bit 24:
Timeout - Cycle time
Bit 25:
Timeout - Task lock
Bit 31:
Unknown error
200009
Enhanced error register 1 (bit-coded)
Bit 3:
Error in ModConfig.da
Bit 10:
A bus node (publish/subscribe client) has
reported an error
Bit 12:
JetIPScan has reported an error
Bit 16:
NetConsistency has reported an error
Bit 24:
IP address conflict detected
200010
Enhanced error register 2 (bit-coded)
Bit 1:
Error in the MC object
200051
Error numbers of JetIPScan
0:
No error or warning
5:
The user has terminated the function
1001:
The first received response does not match
response 2 and 3
1002:
The second received response does not
match response 1 and 3
1003:
The third received response does not match
response 2 and 3
-1:
All three responses are dissimilar
-2:
The IP settings of at least one node are
dissimilar.
-3:
The JetIPScan function has been invoked,
although it is active already
-10:
The length of the set value list is < 1 or
> 255, or the pointer to the list is invalid
-11:
A GNN of the set value list is < 1 or > 255,
or it is a multiple GNN
-20 ... -40: Internal error
-1001 ...
-1199:
The node has reported the wrong CtrlID or
CtrlIDopt
-2001 ...
-2199:
The node has not called
-3001 ...
-3199:
Several nodes of the same GNN have
called
200061
Error numbers of NetConsistency,
see R 470040
200010
Enhanced error register 2 (bit-coded)
Bit 1:
Error in the MC object
200168
Bootloader version (IP format)
200169
OS version (IP format)
200170
Controller type
200300
Currently available heap
200301
Available heap at system launch
200302
Available heap before application program
201000
Runtime register in milliseconds (rw)
201001
Runtime register in seconds (rw)
201002
Runtime register in R 201003
Units (rw)
201003
* 10 ms units for R 201002 (rw)
201004
Runtime register in milliseconds (ro)
201005
Runtime registers in microseconds (ro)
202930
Web status (bit-coded)
Bit 0 = 1:
FTP server available
Bit 1 = 1:
HTTP server available
Bit 2 = 1:
E-mail available
Bit 3 = 1:
Data file function available
Bit 4 = 1:
Modbus/TCP has been licensed
Bit 5 = 1:
Modbus/TCP available
Bit 6:
Reserved
Bit 7 = 1:
FTP client available
202936
Control register of the file system
0xc4697a4b:
Formatting the flash disk
0xd364e64d:
Formatting the SD card
0x2c9b3c94:
Checking the SD card
202960
Password for system command register (0x424f6f74)
202961
System command register
102: Controller restart (reboot)
104: Reset non-volatile parameters
122: Wait for communication - OFF
123: Wait for communication - ON
160: Task switch on I/O access - OFF
161: Task switch on I/O access - ON
170: Continue task time slice - OFF
171: Continue task time slice - ON
310: Load the configuration data
311: Load the module configuration
312: Load process data configuration for Ethernet
system bus
313: Stop Ethernet system bus process data
configuration
330: JetIPScan client - OFF
331: JetIPScan client - ON
410: JetSync blockage - OFF
411: JetSync blockage for all ports - ON
412: JetSync blockage for port X15 - ON
202962
System status register
Bit 0 = 1: Task switch on I/O access
Bit 1 = 1: Without waiting for communication
Bit 2 = 1: JetIPScan client - ON
Bit 3 = 1: Continue task time slice - ON
Bit 8 = 1: JetSync blockage - ON
Содержание JC-120MC
Страница 1: ...User Manual JC 120MC Controller 60880901 We automate your success...
Страница 18: ......
Страница 40: ...40 Jetter AG 3 Identifying Hardware revisions see page 38 Related topics...
Страница 160: ......
Страница 186: ......
Страница 196: ......
Страница 395: ...Jetter AG 395 JC 120MC Programming Result When initializing the JX2 system bus the adjusted baud rate values were used...
Страница 485: ...Jetter AG 485 JC 120MC Programming Topic Page Programming 486 Registers 498 Contents...
Страница 521: ...Jetter AG 521 JC 120MC Programming Use 29 bit identifier Default 11 bit identifier...
Страница 586: ......
Страница 604: ......
Страница 633: ......