542
Jetter AG
10 Programming
Module register properties
Value after reset
Non-volatile; factory setting: 0
Takes effect
Next time when the controller is launched
CAN-Prim status register
R 200010500 allows to evaluate the status of the CAN-Prim interface.
Meaning of the individual bits
Bit 1
NEW-DAT
1 =
At least one message box has received a new CAN message.
Bit 2
Length of CAN ID
0 =
The length of sent/received CAN IDs is 11 bits
1 =
The length of sent/received CAN IDs is 29 bits
Module register properties
Type of access
Read
Takes effect
When the CAN-Prim interface is enabled
CAN-Prim command register
R 200010501 is used to transfer certain commands to the CAN-Prim interface.
CAN-Prim interface - Commands
7
Clear the FIFO buffer
This command is for clearing all entries in the FIFO buffer.
Result: R 200010503 = 0
8
Set the standard ID length to 11 bits
The ID length for all CAN messages is set to 11 bits.
Result:
Bit 2 = 0 in R 200010500
R 200010506 = 0
R 200010507 = 0
R 200 message box number *20 := 0x7FF (in all message boxes)
R 200010500
R 200010501
Содержание JC-120MC
Страница 1: ...User Manual JC 120MC Controller 60880901 We automate your success...
Страница 18: ......
Страница 40: ...40 Jetter AG 3 Identifying Hardware revisions see page 38 Related topics...
Страница 160: ......
Страница 186: ......
Страница 196: ......
Страница 395: ...Jetter AG 395 JC 120MC Programming Result When initializing the JX2 system bus the adjusted baud rate values were used...
Страница 485: ...Jetter AG 485 JC 120MC Programming Topic Page Programming 486 Registers 498 Contents...
Страница 521: ...Jetter AG 521 JC 120MC Programming Use 29 bit identifier Default 11 bit identifier...
Страница 586: ......
Страница 604: ......
Страница 633: ......