428
Jetter AG
10 Programming
Section [POP3]
This section lets you specify the parameters for establishing a connection with
the POP3 server.
Only in case the e-mail server requires authentication via POP3-before-SMTP,
this section is required.
[POP3]
IP = 192.168.40.1
PORT = 25100
USER = JetControl4711
PASSWORD = Pop3PassWord
This type of authentication requires the JC-120MC to log on at the POP3
server. During the logon process USER and PASSWORD must be entered.
After that, the SMTP server allows e-mails to be sent for a given period of time
(usually 10 to 30 minutes).
IP
In the given example
192.168.40.1
Description
IP address of POP3 server;
can also be specified as name.
Allowed values
> 1.0.0.0
< 223.255.255.255
Illegal values
Network address
Broadcast address
In case of illegal value or
missing entry
POP3 log-on will not be carried out.
PORT
In the given example
25.100
Description
Port number of POP3 server
Allowed values
> 0
< 65.536
Illegal values
> 65,335
In case of missing entry
110
Introduction
Example:
Authentication
Configuration values
Содержание JC-120MC
Страница 1: ...User Manual JC 120MC Controller 60880901 We automate your success...
Страница 18: ......
Страница 40: ...40 Jetter AG 3 Identifying Hardware revisions see page 38 Related topics...
Страница 160: ......
Страница 186: ......
Страница 196: ......
Страница 395: ...Jetter AG 395 JC 120MC Programming Result When initializing the JX2 system bus the adjusted baud rate values were used...
Страница 485: ...Jetter AG 485 JC 120MC Programming Topic Page Programming 486 Registers 498 Contents...
Страница 521: ...Jetter AG 521 JC 120MC Programming Use 29 bit identifier Default 11 bit identifier...
Страница 586: ......
Страница 604: ......
Страница 633: ......