544
Jetter AG
10 Programming
FIFO data
R 200010504 shows which of the messages boxes has received the latest
new CAN message. Read access to R 200010504 removes the value which
has been read last from the FIFO buffer. This access decrements the value of
R 200010503 by one.
Note:
Each read access to this register, even via an active JetSym setup screen,
decrements the number of received CAN messages.
Module register properties
Values
No FIFO data available:
-1
Number of the message box
containing new data:
0 ... 15
Type of access
Read access removes
characters
Value after reset
-1
Takes effect
When the CAN-Prim interface is enabled
Global receiving mask
The global receiving mask is for filtering the bits of the received CAN IDs. If
the bit of the global receiving mask is set, the received bit of the CAN ID is
compared with the global receiving ID as shown in R 200010507.
Module register properties
Values
In the case of 11-bit CAN IDs
0 ... 0x7FF
In the case of 29-bit CAN IDs
0 ... 0x1FFFFFFF
Bit = 0
Bit is not compared with R 200010507
Bit = 1
Bit is compared with R 200010507
Takes effect
When the CAN-Prim interface is enabled
R 200010504
R 200010506
Содержание JC-120MC
Страница 1: ...User Manual JC 120MC Controller 60880901 We automate your success...
Страница 18: ......
Страница 40: ...40 Jetter AG 3 Identifying Hardware revisions see page 38 Related topics...
Страница 160: ......
Страница 186: ......
Страница 196: ......
Страница 395: ...Jetter AG 395 JC 120MC Programming Result When initializing the JX2 system bus the adjusted baud rate values were used...
Страница 485: ...Jetter AG 485 JC 120MC Programming Topic Page Programming 486 Registers 498 Contents...
Страница 521: ...Jetter AG 521 JC 120MC Programming Use 29 bit identifier Default 11 bit identifier...
Страница 586: ......
Страница 604: ......
Страница 633: ......