400
Jetter AG
10 Programming
Module register properties
Value after reset
Non-volatile; factory setting: 65,535
Takes effect
Next time when the controller is launched
Baud rate of JX2 system bus
The user configures the baud rate of the JX2 system bus. A reduced baud rate
allows longer lines.
Values
7
1,000 kBaud
6
500 kBaud
5
250 kBaud
4
125 kBaud
Module register properties
Value after reset
Non-volatile; factory setting: 7
Takes effect
Next time when the controller is launched
ON delay
After the JC-120MC has been energized it waits the period given in this
register before it starts initializing the JX2 system bus.
Values
20 ... 600
ON delay from 2 s to 60 s
Module register properties
Value after reset
Non-volatile,
Factory setting: 60 (ON delay = 6 s)
Takes effect
Next time when the controller is launched
R 200002029
R 200002032