15 Quick reference - JC-120(MC)
JetIPScan
Global status information
520000
Summary of status messages
520010
State of execution - Corresponds to the feedback value
State
.
520011
Number of cycles - Corresponds to the feedback value
Count
.
520012
Number of changes - Corresponds to the feedback value
Changed
.
520013
Result of the function - Corresponds to the feedback
value
Result
.
Warnings and errors
521000 ...
521006
All 3 responses are dissimilar
521010 ...
521016
Reply no. 1 is not the same as replies 2 and 3.
521020 ...
521026
Reply no. 2 is not the same as replies 1 and 3.
521030 ...
521036
Reply no. 3 is not the same as replies 1 and 2.
521100 ...
521106
Wrong CtrlID or CtrlIDopt
521200 ...
521206
The node has not called
521300 ...
521306
Multiple call
521400 ...
521406
The IP settings could not be changed
Configuration
522000
GNN
522010 ...
522015
Set configuration
522110 ...
522123
Actual configuration 1
522210 ...
522223
Actual configuration 2
522310 ...
522323
Actual configuration 3
Application registers
1000000 ...
1059999
JC-120(MC): 32-bit integer or floating point number
(non-volatile)
1000000 ...
1119999
JC-120(MC): 32-bit integer or floating point number
(non-volatile); with option -R
JX3 system bus registers
100000000
Bus status
Bit 15 = 1:
Data exchange takes place via JX3 system
bus.
100002000
Hardware revision of the JX3 system bus
100002008
Error register (bit-coded)
Bit 3 = 1:
Error at module access
Bit 16 = 1:
Fatal irrecoverable error has occurred.
Data interchange has been aborted.
100002011
I/O module number where error has occurred
100002013
Number of detected JX3 modules
100002015
Index to module array
100002016
Module array
100002023
Dummy modules
100002034
Number of retries
100002072
Version of the JX3 system bus driver
100002111
Module register number where error has occurred
100002764
Timeout period for register access [ms]
100003xx0 ...
100003xx9
Registers on I/O modules
(compatibility mode)
xx: Module number - 2 (00 ... 15)
100004000
...
100004367
Inputs/outputs mapped to registers
(see below)
100xx0000 …
100xx9999
Registers on I/O modules
(direct access)
xx: Module number (02 ... 17)
JX2 system bus registers
200002000
Version of JX2 system bus driver (IP)
200002008
Error (bit-coded)
Bit 3:
I/O or CANopen® module timeout
Bit 4:
JX2 slave module timeout
Bit 9:
Error of I/O module periphery
Bit 12:
Object length has not been set
Bit 13:
Error during JX2 system bus initialization
Bit 14:
Timeout of system registers
Bit 15:
SDO abort
200002011
I/O module number at timeout
200002012
JX2 slave module number at timeout
200002013
Amount of connected I/O modules
200002014
Amount of connected JX2 slave modules
200002015
Index to module array
200002016
Module array
200002023
Dummy I/O module
200002024
JX2 slave dummy modules
200002028
Monitoring interval for I/O modules [10 ms]
200002029
Baud rate of JX2 system bus
200002032
ON delay
200002039
I/O module where a peripheral fault has occurred
(bit-coded)
200002070
Number of CANopen® modules
200002071
Actual I/O sum of modules on the JX2 system bus
200002072
Version of JX2 system bus driver (IP)
200002073
Timeout for register access to CANopen® modules
200002074
CANopen® SYNC interval [ms]
200002077
Enabling JX2 system bus special functions
JC-120(MC):
Bit 3, 2 = 01:
CAN-Prim in addition to JX2 system
bus
Bit 3, 2 = 10:
CANopen® interface only
(CANopen®-STX-API)
Bit 3, 2 = 11:
CAN-Prim only
Bit 4 = 1:
CAN IDs 0x081 ... 9x09F for CAN-Prim
Bit 6 = 1:
CANopen® feature in the JX2 system
bus driver is deactivated
Bit 6 makes sense only if bit 3 has not
been set
200002080
CANopen® module index for JX2 system bus application
registers
200002085
SysBus application registers:
Register number (65-89)
200002086
SysBus application registers:
Object number
200002087
SysBus application registers: Sub-index
200002088
SysBus application registers: Length
200002760
Max. number of I/O update retries
200002761
Index to array of I/O retry counters
200002762
Array of I/O retry counters
Содержание JC-120MC
Страница 1: ...User Manual JC 120MC Controller 60880901 We automate your success...
Страница 18: ......
Страница 40: ...40 Jetter AG 3 Identifying Hardware revisions see page 38 Related topics...
Страница 160: ......
Страница 186: ......
Страница 196: ......
Страница 395: ...Jetter AG 395 JC 120MC Programming Result When initializing the JX2 system bus the adjusted baud rate values were used...
Страница 485: ...Jetter AG 485 JC 120MC Programming Topic Page Programming 486 Registers 498 Contents...
Страница 521: ...Jetter AG 521 JC 120MC Programming Use 29 bit identifier Default 11 bit identifier...
Страница 586: ......
Страница 604: ......
Страница 633: ......