background image

 

Copyright © BRT Systems Pte Ltd          

 

 

 

 

    

           1

 

 

 LDSBus IR Blaster Datasheet Blaster Datasheet  

Version 1.1 

 

Document Reference No.: BRTSYS_000003    Clearance No.: BRTSYS#004 

 

 

 

 

LDSBus IR Blaster 

Datasheet  

 

 

 

 

 

 

 

 

 

  

 

 

 

   

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 
 

 
 
 
 
Neither the whole nor any part of the information contained in, or the product described in this manual, may be adapted, or reproduced 
in  any  material  or  electronic  form  without  the  prior  written  consent  of  the  copyright  holder.  This  product  and  its  documentation  are  
supplied on an as-is basis and no warranty as to their suitability for any particular purpose is either made or implied. BRT Systems Pte 
Ltd will not accept any claim for damages howsoever arising as a result of use or failure of this product. Your statutory rights are not 
affected. This product or any variant of it is not intended for use in any medical appliance, device, or system in which the failure of the 

product might reasonably be expected to result in personal injury. This document provides preliminary information that may be subject 
to change without notice. No freedom to use patents or other intellectual property rights is implied by the publication of this document. 
BRT Systems Pte Ltd, 178 Paya Lebar Road, #07-03, Singapore 409030. Singapore Registered Company Number: 202220043R. 

 

 

1.1

 

Features  

 

 

LDSBus IR Blaster consists of on-board IR 
emitters in a compact device 

 

 

360

o

 of IR coverage  

 

 

Maximum emission range: 7 meters 
 

 

BRTSYS LDSBus protocol. Wired data and 
power transmission through LDSBus HVT-
Junction. 
 

 

Low power consumption 

 625mW (typical) 

 

 

Operating temperature range : 0

o

C to +70

o

 

 

Swivel and flush mount options 
 

 

Supported platform applications:  

 

BRTSYS PanL Smart Living product and 
LDSBus Python SDK  
 
(Visit 

https://brtsys.com/resources

) 

 
 

1

 

Introduction 

 

The LDSBus IR Blaster replaces traditional 
single device IR remote controllers to 
function as a universal remote controller. 
The IR Blaster is equipped with 7 high power 
IR LEDs that provide 360

of coverage 

ranging up to 7 meters. The LDSBus IR 
Blaster is suitable for controlling Air- 
conditioners, TVs, Set-Top Boxes, curtains 
and blinds, fans and many more appliances. 

Summary of Contents for LDSBus LC020101A-F

Page 1: ...t provides preliminary information that may be subject to change without notice No freedom to use patents or other intellectual property rights is implied by the publication of this document BRT Systems Pte Ltd 178 Paya Lebar Road 07 03 Singapore 409030 Singapore Registered Company Number 202220043R 1 1 Features LDSBus IR Blaster consists of on board IR emitters in a compact device 360o of IR cove...

Page 2: ...2 LDSBus IR Blaster Datasheet Blaster Datasheet Version 1 1 Document Reference No BRTSYS_000003 Clearance No BRTSYS 004 2 Part Numbers Part Naming LC020101A F LDSBus IR Blaster Flush Mount LC020101A S LDSBus IR Blaster Swivel Mount ...

Page 3: ...duct Specifications 4 4 Hardware Features 5 5 Configuration Installation and Application 6 5 1 Connection Diagram 6 6 Mounting Instructions 7 6 1 Flush Mount 7 6 2 Swivel Mount 8 7 System Status LED Indicator 10 8 Mechanical Dimension 11 9 Contact Information 12 Document References 13 Acronyms and Abbreviations 13 Appendix B List of Figures and Tables 14 List of Figures 14 List of Tables 14 Append...

Page 4: ...tallation Power Input Voltage 5V DC Bus Power Typical Power 620mW Max Power 1150mW IR Emitter Range 7 Meters Maximum Angle 360 Degree Physical Characteristics Color White Housing Polycarbonate Dimensions 62mm x H25mm Flush or 62mm x H60mm Swivel Environmental Limits Operating Temperature 0 to 70 C Storage Temperature 20 to 85 C Ambient Relative Humidity 5 to 95 non condensing Package Contents Devi...

Page 5: ...atasheet Version 1 1 Document Reference No BRTSYS_000003 Clearance No BRTSYS 004 4 Hardware Features Figure 1 LDSBus IR Blaster Swivel Mount Figure 2 LDSBus IR Blaster Flush Mount IR Emitter LED Status Indicator Mounting Screw Location Lock Direction Flush Mount Bracket ...

Page 6: ...ific application 5 1 Connection Diagram Figure 3 illustrates the connection of the LDSBus IR Blaster LDSBus Device to the LDS Bus Please visit https brtsys com resources to view the full device application setup and installation guides Setup Instructions 1 Connect the first LDSBus HVT Junction to any of the LDSBus Host Systems using a RJ45 CAT5e cable 2 Connect the configured LDSBus IR Blaster to ...

Page 7: ...pening Figure 4 shows the front face of the LDSBus IR Blaster Note the lock unlock direction on the cover Figure 4 LDSBus IR Blaster Flush Mount Top View Follow these steps to fix the swivel mount 1 Unlock the back cover Twist the top cover in the anti clockwise direction to unlock 2 Make two holes in the back cover using the indentations as guides 3 Prepare the ceiling and route the RJ12 JST cabl...

Page 8: ...shown in Figure 5 Figure 5 LDSBus IR Blaster Swivel Mount Top Bottom View Follow these steps to fix the swivel mount 1 Choose the position for the wall mount and drill holes for mounting the swivel mount on the wall 2 Route and affix the LDSBus RJ11 cable on the wall through a buried or wall mounted conduit to butt against the base of the swivel mount 3 Break off one of the three cable entry locat...

Page 9: ...the wall using the mounting screws Ensure that the cable is sitting in the cable entry slot 6 Remove the sensor from the flush mount back cover by turning it in an anti clockwise direction 7 Connect the JST cable from the top section of the swivel mount to the JST connector located on the back of the device 8 Attach the device to the top section of the swivel mount 9 Turn the device clockwise to s...

Page 10: ...tus LED Indicator LED status are illustrated in Table 2 Device Status LED Color Flashing Frequency Description Idle OFF LED Off Unconfigured device with factory default address 126 Transmitting RED LED flashing 5Hz Device transmitting IR signals Firmware update YELLOW Steady Non flashing Device firmware update Table 2 LDSBus IR Blaster System Status LED Indicator ...

Page 11: ...atasheet Blaster Datasheet Version 1 1 Document Reference No BRTSYS_000003 Clearance No BRTSYS 004 8 Mechanical Dimension Figure 6 LDSBus IR Blaster Dimension Top View Figure 7 LDSBus IR Blaster Dimension Side View Note All dimensions are in millimetres ...

Page 12: ...ing application descriptions suggested BRT Systems devices and other materials is provided for reference only While BRT Systems has taken care to assure it is accurate this information is subject to customer confirmation and BRT Systems disclaims all liability for system designs and for any applications assistance provided by BRT Systems Use of BRT Systems devices in life support and or safety app...

Page 13: ...cument Reference No BRTSYS_000003 Clearance No BRTSYS 004 Appendix A References Document References BRTSYS_AN_001_LDSBus_Configuration_Utility_User_Guide BRTSYS_AN_002_LDSU IR Blaster_Application Acronyms and Abbreviations Terms Description DC Direct Current LED Light Emitting Diode IR Infrared ...

Page 14: ...wivel Mount 5 Figure 2 LDSBus IR Blaster Flush Mount 5 Figure 3 LDSBus IR Blaster to LDS Bus Connection Diagram 6 Figure 4 LDSBus IR Blaster Flush Mount Top View 7 Figure 5 LDSBus IR Blaster Swivel Mount Top Bottom View 8 Figure 6 LDSBus IR Blaster Dimension Top View 11 Figure 7 LDSBus IR Blaster Dimension Side View 11 List of Tables Table 1 LDSBus IR Blaster Specifications 4 Table 2 LDSBus IR Bla...

Page 15: ...nce No BRTSYS 004 Appendix C Revision History Document Title LDSBus IR Blaster Datasheet Document Reference No BRTSYS_000003 Clearance No BRTSYS 004 Product Page https brtsys com ldsbus Document Feedback Send Feedback Revision Changes Date Version 1 0 Initial Release 16 11 2021 Version 1 1 Updated release under BRT Systems 14 09 2022 ...

Reviews: