HD2 IP55 High-ingress Protection Series
Function parameter list
-133-
Function
code
Name
Description
Default
value Modify
P03.31
Corresponding
frequency of
high speed
friction torque
–400.00Hz
50.00Hz
○
P03.32 Torque control
enable
0:Disable
1:Enable
0
◎
P03.33 Flux weakening
integral gain 0–8000
1200
○
P03.34
Reserved
/
/
/
P03.35
Control
optimization
setting
0–0x1111
Ones place: Torque command selection
0: Torque reference
1: Torque current reference
Tens place: Reserved
0: Reserved
1: Reserved
Hundreds place: Whether to enable ASR
integral separation
0: Disable
1: Enable
Thousands place: Reserved
0: Reserved
1: Reserved
0x0000
○
P03.36
Speed loop
differential gain 0.00–10.00s
0.00s
○
P03.37
High-frequency
current loop
proportional
coefficient
Under closed-loop vector control mode
=3) and
, the current loop PI
; above
, the PI parameters are
and
Setting range of
: 0–65535
Setting range of
: 0–65535
Setting range of
: 0.0–100.0% (relative
to max. frequency)
1000
○
P03.38
High-frequency
current loop
integral
coefficient
1000
○
P03.39
Current loop
high-frequency
switch-over
point
100.0%
○
P03.40
Inertia
compensation
enable
0: Disable
1: Enable
0
○
P03.41
Upper limit of
inertia
compensation
torque
Limit the max. inertia compensation torque to
prevent inertia compensation torque from
being too large.
Setting range: 0.0–150.0% (rated motor
torque)
10.0%
○
Содержание HD2 IP Series
Страница 1: ......
Страница 16: ......
Страница 40: ......
Страница 107: ......
Страница 176: ...HD2 IP55 High ingress Protection Series Inverter 162 Function parameter list...
Страница 213: ......
Страница 271: ...HD2 IP55 High ingress Protection Series Troubleshooting 251 7 6 8 Overcurrent...
Страница 294: ...HD2 IP55 High ingress Protection Series Inverter 274...
Страница 360: ...HD2 IP55 High ingress Protection Series Inverter 340...
Страница 361: ......