HD2 IP55 High-ingress Protection Series Inverters
Basic Operation Instructions
-32-
Area
Name
Displayed contents
inverter is in stop state (no fault); "Run" – The
inverter is in running state; "Jog"–The inverter is in
jogging state; "Pre-alarm"–the inverter is under pre-
alarm state during
running; "Fault"–inverter fault occurred.
Header C inverter station no.
and model display
area
1. Display inverter station no.: 01–99, applied in multi-
drive applications (reserved function);
2. inverter model display: "HD2IP–current inverter is
HD2IP series inverter.
Display D
The parameter name
and function code
monitored by the
inverter
Display the parameter name and corresponding function
code monitored by the inverter; three monitoring
parameters can be displayed simultaneously. The
monitoring
parameter list can be edited by the user
Display E
Parameter value
monitored by the
inverter
Display the parameter value monitoring by the inverter,
the monitoring value will be refreshed in real time
Footer F
Corresponding menu
of function key (4), (5)
and (6)
Corresponding menu of function key (4), (5) and (6). The
corresponding menu of function key (4), (5) and (6) varies
with interfaces, and the contents displayed in this area is
also different
5.3 Keypad display
The display state of HD2IP series keypad is divided into stop parameter display state, running
parameter display state and fault alarm display state.
5.3.1 Stop parameter display state
When the inverter is in stop state, the keypad displays stop state parameters, and this interface
is the main interface during power-up by default. Under stop state, parameters in various states
can be displayed. Press
or
to shift the displayed parameter up or down.
Figure 5-3 Stop parameter display state
16:02:35 Forward Local Ready 01: HD2IP
DC bus voltage
P17.11 V
540.0
Digital input terminal state
P17.12
0x0000
Digital output terminal state
P17.13
0x0000
Monitoring
About
Menu
Press
or
to switch between different display styles, including list display style and
progress bar display style.
16:02:35 Forward Local
Ready
01: HD2IP
Set frequency
P17.00 Hz
50.00
DC bus voltage
P17.11 V
540.0
Digital input terminal state
P17.12
0x0000
Monitoring
About
Menu
Содержание HD2 IP Series
Страница 1: ......
Страница 16: ......
Страница 40: ......
Страница 107: ......
Страница 176: ...HD2 IP55 High ingress Protection Series Inverter 162 Function parameter list...
Страница 213: ......
Страница 271: ...HD2 IP55 High ingress Protection Series Troubleshooting 251 7 6 8 Overcurrent...
Страница 294: ...HD2 IP55 High ingress Protection Series Inverter 274...
Страница 360: ...HD2 IP55 High ingress Protection Series Inverter 340...
Страница 361: ......