HD2 IP55 High-ingress Protection Series
Function parameter list
-159-
P08 group––Enhanced functions
Function
code
Name
Description
Default
value Modify
P08.00
Acceleration
time 2
See
and
P00.12
for detailed
definitions.
The
HD2
IP55
high
protectionhigh-ingress protectionGoodrive350
series inverter defines four groups of
acceleration/deceleration time, which can be
selected by multi-function digital input terminal
(P05 group). The acceleration/deceleration
time of the inverter is the first group by default.
Setting range: 0.0–3600.0s
Depend
on model
○
P08.01
Deceleration
time 2
Depend
on model
○
P08.02
Acceleration
time 3
Depend
on model
○
P08.03
Deceleration
time 3
Depend
on model
○
P08.04
Acceleration
time 4
Depend
on model
○
P08.05
Deceleration
time 4
Depend
on model
○
P08.06
Running
frequency of
jogging
This function code is used to define the
reference frequency of the inverter during
jogging.
Setting range: 0.00Hz–
(max. output
frequency)
5.00Hz
○
P08.07
Acceleration
time of jogging
Jogging acceleration time is the time needed
for the inverter to accelerate from 0Hz to max.
output frequency (
Jogging deceleration time is the time needed
from decelerating from the max. output
frequency (
) to 0Hz.
Setting range: 0.0–3600.0s
Depend
on model
○
P08.08
Deceleration
time of jogging
○
P08.09 Jump frequency
1
When the set frequency is within the range of
jump frequency, the inverter will run at the
boundary of jump frequency.
The inverter can avoid mechanical resonance
point by setting the jump frequency, and three
jump frequency points can be set. If the jump
frequency points are set to 0, this function will
be invalid.
Setting range: 0.00Hz–
(max. output
frequency)
0.00Hz
○
P08.10 Jump frequency
amplitude 1
0.00Hz
○
P08.11 Jump frequency
2
0.00Hz
○
P08.12 Jump frequency
amplitude 2
0.00Hz
○
P08.13 Jump frequency
3
0.00Hz
○
P08.14 Jump frequency
amplitude 3
0.00Hz
○
Содержание HD2 IP Series
Страница 1: ......
Страница 16: ......
Страница 40: ......
Страница 107: ......
Страница 176: ...HD2 IP55 High ingress Protection Series Inverter 162 Function parameter list...
Страница 213: ......
Страница 271: ...HD2 IP55 High ingress Protection Series Troubleshooting 251 7 6 8 Overcurrent...
Страница 294: ...HD2 IP55 High ingress Protection Series Inverter 274...
Страница 360: ...HD2 IP55 High ingress Protection Series Inverter 340...
Страница 361: ......