HD2 IP55 High-ingress Protection Series
Troubleshooting
-249-
7.6.6 inverter overheating
Whether the load is too
heavy, or the capacity of
the inverter is too small?
No
Yes
Whether the ambient
temperature is too
high?
No
Yes
Whether the fan of the
inverter is abnormal?
No
Yes
Whether the heat sink
is blocked?
Yes
No
Whether the carrier
frequency is too high?
No
Yes
inverter overheating
If it is an inverter
fault, contact our
company
Reduce the carrier
frequency
Clean the heat sink to
improve the cooling
conditions
If it is an inverter
fault, contact IMO
Add a cooling device
or derate the
inverter
Reduce the load and
increase the capacity
of the inverter