5.
Use the “Licensed Internal Code log” service function under DST/SST to copy
the LIC log entries to removable media for the day that the problem occurred.
6.
Copy the system configuration list (see “Hardware Service Manager, Printing
the System Configuration List” in the
iSeries Service Functions
information).
7.
Provide the dumps to IBM Service Support.
8.
Check the Logical Hardware Resource STATUS field using Hardware Service
Manager. If the status is not
Operational
then IPL the IOP using the I/O Debug
option (Ignore resources with a status of
not connected)
.
To IPL a failed IOP, the following command can be used:
VRYCFG CFGOBJ(XXXX)
CFGTYPE(*CTL) STATUS(*RESET)
or use DST/SST Hardware Service Manager.
If the IPL does not work:
v
Check the Service Action Log for new SRC entries (see “Using the Service
Action Log” on page 9). Use the new SRC and go to “Chapter 2. Unit
Reference Codes” on page 59.
v
If there are no new SRCs in the Service Action Log, go to “BUS-PIP1” on
page 285.
This ends the procedure.
9.
Has the system stopped but the DST console is still active (Did the SRC come
from the Main Storage Dump manager screen on the DST console)?
Yes
No
↓
Go to step 15 of this procedure.
10.
Complete a Problem Summary Form using the information in words 1–9 from
the control panel, or from the DST Main Storage Dump screen (see “Error
Recovery for Dumps, Reporting the Error” in the
iSeries Service Functions
information).
11.
The system has already taken a partial main storage dump for this SRC and
automatically re-IPLed to DST (see “Automatic Main Storage Dump” in the
iSeries Service Functions
information).
12.
Copy the main storage dump to tape (see “Copying a Main Storage Dump” in
the
iSeries Service Functions
information).
13.
When the dump is completed, the system will re-IPL automatically. Sign on to
DST or SST. Obtain the data in steps 3, 4, 5, and 6 of this procedure.
14.
Provide the dumps to IBM Service Support.
This ends the procedure.
15.
Has the system stopped with an SRC at the control panel?
Yes
No
↓
Go to step 1 of this procedure.
16.
Complete a Problem Summary Form using the information in words 1–9 from
the control panel, or from the DST Main storage dump screen (see “Error
Recovery for Dumps, Reporting the Error” in the
iSeries Service Functions
information).
17.
IPL to DST and start the Main storage dump manager service function.
18.
Copy the main storage dump to tape (see “Copying a Main Storage Dump” in
the
iSeries Service Functions
information).
19.
Obtain the data in steps 3, 4, 5, and 6 of this procedure.
20.
Re-IPL the system.
21.
Has the system stopped with an SRC at the control panel?
LIC PIPs
Chapter 3. Problem Isolation Procedures (PIPs), Failing Items, and Symbolic FRU Isolation
343
Содержание i 830
Страница 1: ...iSeries iSeries Model 830 840 SB2 and SB3 Problem Analysis Repair and Parts Version 5 SY44 5969 01...
Страница 2: ......
Страница 3: ...iSeries iSeries Model 830 840 SB2 and SB3 Problem Analysis Repair and Parts Version 5 SY44 5969 01...
Страница 14: ...xii iSeries Model 830 840 SB2 and SB3 Problem Analysis Repair and Parts V5R1...
Страница 15: ...Part 1 Problem Analysis Copyright IBM Corp 2000 2001 1...
Страница 16: ...2 iSeries Model 830 840 SB2 and SB3 Problem Analysis Repair and Parts V5R1...
Страница 628: ...Symbolic FRUs 614 iSeries Model 830 840 SB2 and SB3 Problem Analysis Repair and Parts V5R1...
Страница 629: ...Part 2 FRU Replacement Copyright IBM Corp 2000 2001 615...
Страница 630: ...616 iSeries Model 830 840 SB2 and SB3 Problem Analysis Repair and Parts V5R1...
Страница 817: ...Part Assemblies Chapter 5 Locations Addresses and Part Listings 803...
Страница 822: ...Assembly 2 continued 808 iSeries Model 830 840 SB2 and SB3 Problem Analysis Repair and Parts V5R1...
Страница 824: ...Assembly 2 continued 810 iSeries Model 830 840 SB2 and SB3 Problem Analysis Repair and Parts V5R1...
Страница 826: ...Assembly 2 continued 812 iSeries Model 830 840 SB2 and SB3 Problem Analysis Repair and Parts V5R1...
Страница 830: ...Assembly 3 continued 816 iSeries Model 830 840 SB2 and SB3 Problem Analysis Repair and Parts V5R1...
Страница 832: ...Assembly 3 continued 818 iSeries Model 830 840 SB2 and SB3 Problem Analysis Repair and Parts V5R1...
Страница 834: ...Assembly 3 continued 820 iSeries Model 830 840 SB2 and SB3 Problem Analysis Repair and Parts V5R1...
Страница 836: ...Assembly 3 continued 822 iSeries Model 830 840 SB2 and SB3 Problem Analysis Repair and Parts V5R1...
Страница 844: ...Assembly 6 continued 830 iSeries Model 830 840 SB2 and SB3 Problem Analysis Repair and Parts V5R1...
Страница 848: ...Assembly 7 continued 834 iSeries Model 830 840 SB2 and SB3 Problem Analysis Repair and Parts V5R1...
Страница 850: ...Assembly 7 continued 836 iSeries Model 830 840 SB2 and SB3 Problem Analysis Repair and Parts V5R1...
Страница 858: ...Assembly 10 continued 844 iSeries Model 830 840 SB2 and SB3 Problem Analysis Repair and Parts V5R1...
Страница 860: ...Assembly 10 continued 846 iSeries Model 830 840 SB2 and SB3 Problem Analysis Repair and Parts V5R1...
Страница 862: ...Assembly 10 continued 848 iSeries Model 830 840 SB2 and SB3 Problem Analysis Repair and Parts V5R1...
Страница 864: ...Assembly 10 continued 850 iSeries Model 830 840 SB2 and SB3 Problem Analysis Repair and Parts V5R1...
Страница 870: ...Assembly 12 continued 856 iSeries Model 830 840 SB2 and SB3 Problem Analysis Repair and Parts V5R1...
Страница 872: ...Assembly 12 continued 858 iSeries Model 830 840 SB2 and SB3 Problem Analysis Repair and Parts V5R1...
Страница 874: ...Assembly 12 continued 860 iSeries Model 830 840 SB2 and SB3 Problem Analysis Repair and Parts V5R1...
Страница 876: ...Assembly 12 continued 862 iSeries Model 830 840 SB2 and SB3 Problem Analysis Repair and Parts V5R1...
Страница 882: ...Assembly 14 continued 868 iSeries Model 830 840 SB2 and SB3 Problem Analysis Repair and Parts V5R1...
Страница 888: ...Assembly 16 continued 874 iSeries Model 830 840 SB2 and SB3 Problem Analysis Repair and Parts V5R1...
Страница 894: ...Assembly 19 External Cables External Cables 880 iSeries Model 830 840 SB2 and SB3 Problem Analysis Repair and Parts V5R1...
Страница 897: ...Miscellaneous Chapter 5 Locations Addresses and Part Listings 883...
Страница 898: ...Assembly 20 Miscellaneous Miscellaneous 884 iSeries Model 830 840 SB2 and SB3 Problem Analysis Repair and Parts V5R1...
Страница 906: ...892 iSeries Model 830 840 SB2 and SB3 Problem Analysis Repair and Parts V5R1...
Страница 962: ...948 iSeries Model 830 840 SB2 and SB3 Problem Analysis Repair and Parts V5R1...
Страница 963: ...Part 3 Appendixes Copyright IBM Corp 2000 2001 949...
Страница 964: ...950 iSeries Model 830 840 SB2 and SB3 Problem Analysis Repair and Parts V5R1...
Страница 968: ...954 iSeries Model 830 840 SB2 and SB3 Problem Analysis Repair and Parts V5R1...
Страница 970: ...956 iSeries Model 830 840 SB2 and SB3 Problem Analysis Repair and Parts V5R1...
Страница 974: ...960 iSeries Model 830 840 SB2 and SB3 Problem Analysis Repair and Parts V5R1...
Страница 980: ...966 iSeries Model 830 840 SB2 and SB3 Problem Analysis Repair and Parts V5R1...
Страница 982: ...968 iSeries Model 830 840 SB2 and SB3 Problem Analysis Repair and Parts V5R1...
Страница 984: ...970 iSeries Model 830 840 SB2 and SB3 Problem Analysis Repair and Parts V5R1...
Страница 986: ...972 iSeries Model 830 840 SB2 and SB3 Problem Analysis Repair and Parts V5R1...
Страница 990: ...976 iSeries Model 830 840 SB2 and SB3 Problem Analysis Repair and Parts V5R1...
Страница 999: ......
Страница 1000: ...Printed in the United States of America on recycled paper containing 10 recovered post consumer fiber SY44 5969 01...