Page 9-22
140-590032-0007
Revision A4: Sep, 2010
Section III Sub-section 9
ELECTRICAL POWER
Pilot’s Operating Manual
AC POWER DISTRIBUTION
Two main busbars XS 1 and XS 2 and an essential busbar XE are provided. During normal operation,
busbars XS 1 and XE are fed by No. 1 inverter and XS 2 by No. 2 inverter.
In the event of a single main inverter failure, the remaining main inverter output will be automatically
switched to supply all three busbars. If failure of both main inverters should occur, essential services
supplied from busbar XE will be maintained by the standby inverter.
XS 1
XS 2
XE
PS 1
PS 2
PE
XS 1
FAIL
INV 1
FAIL
XS 2
FAIL
INV 2
FAIL
STBY INV
ON
XE
FAIL
Figure 8
Inverter System Busbars - Simplified
STOP
INV 1
START
STOP
STBY INV
STOP
INV 2
START
START
STBY INVERTER
No. 1 INVERTER
No. 2 INVERTER
AUTO TRANSFER
STALL
VANE
HEAT