Page 2-24
Pilot’s Operating Manual
Revision A2: Nov, 2004
Sub-section 2
GROUND SERVICING
Hawker 800XP Pro Line 21
Section VI - GROUND OPERATIONS
Defueling
Preparation for Suction Defueling
Specific preparations are provided below for airplanes which have Service Bulletin SB 24-3641
incorporated or do not have Service Bulletin SB 24-3641 incorporated:
I. Airplane Serial No. 258670 and subsequent, or airplanes with Raytheon Aircraft Company
Service Bulletin SB 24-3641 incorporated and suction defueling with the airplane batteries
only:
II. Airplanes prior to Serial No. 258670 which do not have Raytheon Aircraft Company
Service Bulletin SB 24-3641 incorporated and suction defueling with the airplane batteries
only:
III. All airplanes suction defueling when external power or the APU is available:
Depending on the configuration of the airplane, refer to the appropriate steps under I, II, or III to prepare
for Suction Defueling:
I. Airplane Serial No. 258670 and subsequent, or airplanes with Raytheon Aircraft Company Service
Bulletin SB 24-3641 incorporated and suction defueling with the airplane batteries only:
(1) Calculate fuel quantity to be off-loaded.
NOTE: For airplanes equipped with a ventral tank, the ventral tank must be off-loaded
completely with any precise load adjustments made in the wing tanks.
CAUTION: INVESTIGATE ANY CONTAMINATION, OTHER THAN WATER, OF THE FOLLOWING
DRAINED SAMPLE.
(2) Drain all water from the tanks (Figures 6 & 8).
WARNING:APU (if installed) MUST NOT BE RUNNING.
(3) On the refuel control panel, select the POWER switch ON (Figure 6).
NOTE: A sonalert will sound and the overhead panel REFUEL ON annunciator will
illuminate when the POWER switch is selected ON. The sonalert will stop
when the MASTER switch is selected ON.
Engine/Fuel data page will automatically be displayed on the pilot’s CDU.
(4) If the wings are to be only partially defueled, check the wing FUEL contents displayed
on the pilot’s CDU and make sure the indication shows the correct current fuel state.
(5) Comply with local refueling safety precautions.
(6) Refer forward to Suction Defueling Procedure and continue with steps 1 thru 14: