Page 2-34
Pilot’s Operating Manual
Revision A2: Nov, 2004
Sub-section 2
GROUND SERVICING
Hawker 800XP Pro Line 21
Section VI - GROUND OPERATIONS
Equipment Required:
• Gravity Defuel Drain Adapter P/N 25Y867A (Figure 11).
• Suction Defuel Drain Adapter P/N 25Y635A.
NOTES:
1. 25Y867A is a sub-assembly of 25Y635A and can be obtained separately.
2. Fuel may be off-loaded by gravity into a container, or by suction into a refuel vehicle
or hydrant.
(1) Calculate fuel load required.
CAUTION: INVESTIGATE ANY CONTAMINATION, OTHER THAN WATER, IN THE FOLLOWING
DRAINED SAMPLE.
(2) Drain all water from the tanks.
(3) Comply with local refueling safety precautions.
(4) Bond the refuel vehicle, hydrant or container to the airplane.
(5) Place a wing skin protection mat on the wing at the filling point for the tank being
defueled (Figure 9).
(6) Unlock and remove the filler cap.
(7) Unscrew the blanking adapter from the fuel drain valve and install the drain adapter to
the tank.
NOTE: 25Y867A is for gravity defuel, 25Y635A is for suction defuel.
(8) Off-load fuel as required from each tank.
(9) Remove the drain adapter and install the blanking adapter to the fuel drain valve.
(10) Reinstall the filler cap(s) and lock.
(11) Remove the wing skin protection mat.
Содержание Hawker 800XP